Multi Variable Air Conditioners Indoor Unit for North America

4.2 Four-way Cassette Type Indoor Unit

Step
1. Unscrew the
water tray.
2. Remove the
water tray.
3. Unscrew the
centrifugal fan.
4. Remove the
centrifugal fan.
5. Unscrew the
motor.
6. Replace the
motor with a new
one.
7. Screw the
motor.
Motor and fan
Diagram
Loosen the
screws
118
Operation Procedure
●Use a screwdriver to unscrew the
water tray.
●Remove the water tray.
●Use a wrench to unscrew the
centrifugal fan.
●Remove the centrifugal fan.
●Use a screwdriver to unscrew the
motor.
●Replace the motor with a new one.
●Use a screwdriver to screw the
motor.