Installing the Water Temperature Sensor
9.
Install the sensor o-ring onto the end of the sensor.
10. Insert the sensor and o-ring into the hole in the pipe. See Figure 2.
11.
Wrap the clamp around the pipe and over the sensor. Tighten the clamp nut to
secure the clamp and sensor onto the pipe with a flat-head screwdriver.
See Figure 2.
12. Run a 22 AWG (provided with the sensors), two-conductor cable from the sensor
to the IntelliSync Temperature Water screw terminals.
13. Strip back the outer jacket of the cable by 1-inch, exposing the two conductors.
Strip back each conductor 1/4-inch.
14. Insert the conductors into the Temperature Water sensor screw terminals.
Secure the individual wires in screw terminals. See WATER temperature screw
terminal illustration on previous page.
3/8" Drill
2" or 3" Pipe
IntelliSync Control and Monitoring System
Replacement Parts
• Water/Air Temperature Sensor Kit (P/N 520872)
• Temperature Sensor, 10k Ohms, 40 ft - P/N 521583
• Temperature Sensor, 10k Ohms, 20 ft - P/N 521584
• Hose Clamp (1-7/8" - 5" Clamp) - P/N 476168
• Hose Clamp 2-3/4 IN – P/N 9321004
• IntelliSync Unit
• Top Cover
• Power Supply
• Terminal Plug (2 Position)
• Terminal Plug (4 Position)
• Terminal Plug (6 Position)
IntelliSync® Water Sensor Installation
IntelliSync Control and Monitoring System Installation Guide
(Continued)
P/N 523404
P/N 523413
P/N 523410
P/N 8023302
P/N 8023304
P/N 8023306
Tighten clamp nut
Water Sensor
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents