Connecting a SuperFlo® and SuperMax® VS Pump to IntelliSync
Digital Input Voltage Specifications: 18-30 VAC (24 VAC +/- 20%) - 9-30 VDC
(12-24 VDC +/- 20%)
Connecting Legacy pumps (SuperFlo VS Pump (P/N 342000) and SuperMax VS
Pump (P/N 343000) to IntelliSync:
1.
Unplug power from the IntelliSync Control and Monitoring unit. See page 11.
2.
Use a 25 ft. (7.62 m) or 50 ft. (15.2 m) low voltage, six conductor low voltage control
cable. External Control Wiring Kit (P/N 353129Z), sold separately.
3.
Strip back the outer jacket of the cable by 1-inch, exposing the conductors. Strip
back each conductor 1/4-inch. Insert and secure the five (5) conductors into the
pump's DIP switch digital output terminals as shown below:
4.
Run the cable from the pump to the IntelliSync unit screw terminals. Strip back
the outer jacket of the cable by 1-inch, exposing the conductors. Strip back each
conductor 1/4-inch. Insert and secure five (5) conductors into the IntelliSync
SuperFlo VS digital output screw terminals as shown below:
GREEN (STEP 1), YELLOW (STEP 2), ORANGE (STEP 3), BROWN (OVRD),
BLACK (ICOM).
5.
Add a wire from J3 (RED (+), RS-485 4-pin connector) to J8 (RED- SuperFlo
6-pin connector) as shown below.
Note: If the pump has been
stopped via the Start/Stop button,
the pump will not run until the
pump is turned back on by pressing
the Start/Stop button. If the
Start/Stop LED is illuminated, that
indicates the pump is on and will
run via Digital Inputs.
Note: When multiple low voltage
triggers are present priority will
be: PROGRAM 1 > PROGRAM 2 >
PROGRAM 3 > QUICK CLEAN.
Access to the SuperFlo VS terminals are
in close proximity to the AC power mains
connectors which carry line voltage capable
of causing personal injury or damaging the
equipment if contact is made. AC Power
to the pump should be turned off when
accessing this area.
IntelliSync Control and Monitoring System Installation Guide
J3
Pump Input Connector
SuperFlo VS Pump
(Wiring Compartment Cover Removed)
IntelliSync SuperFlo® VS
Wiring Terminals
SuperFlo® VS