Installing the Ambient Air Temperature Sensor
Install the air sensor in a shady area (not in direct sunlight) near the equipment pad.
Refer to sensor manual for specific sensor installation instructions.
To wire the air temperature sensor to IntelliSync Control and Monitoring System:
1.
Unplug power from the IntelliSync unit. See page 11.
2.
Run a 22 AWG (provided with the sensors), two-conductor cable from the Air
Sensor to the IntelliSync Air sensor screw terminals.
3.
Strip back the outer jacket of the cable by 1-inch, exposing the two conductors.
Strip back each conductor 1/4-inch.
4.
Insert the conductors into the Temperature AIR sensor screw terminals. Secure
the individual wires into the screw terminal. See AIR temperature screw terminal
illustration below.
Installing the Water Temperature Sensor
Install the water temperature sensor into the plumbing system between the
filtration pump and filter. Refer to sensor installation manual (P/N 520326) for
A licensed plumber should perform all plumbing installation, as they will be
familiar with all local, state and national codes.
Required Tools: Electric Drill, 3/8" Drill Bit, and a Flat-Head Driver
1.
Unplug power from the IntelliSync unit, see page 11.
2.
Be sure all power to the filtration pump is turned OFF at the circuit breaker to
prevent unexpected start-ups during installation.
Failure to relieve all pressure from the filtration system before installing this
equipment may result in serious injury.
3.
Relieve all pressure from the filtration system at the filter.
4.
Close all valves to prevent flooding.
5.
Heater installed: Install the water sensor between the filter and heater. Mark the
pipe where the sensor will be installed.
6.
No heater installed: Install the water sensor between the filter pump and filter.
Mark the pipe where the sensor will be installed.
7.
Set the electric drill to low speed. Drill a 3/8" hole (2 in or 3 in pipe) at the mark
made in the pipe. Gently deburr the hole. See Figure 1 on next page.
IntelliSync Control and Monitoring System Installation Guide
IntelliSync® AIR and WATER Screw Terminals
H1
H2
S1
S2