Pentair HAFFMANS RPU-352 Instruction Manual

Pentair HAFFMANS RPU-352 Instruction Manual

Redpost pu monitor
Table of Contents

Advertisement

HAFFMANS
HAFFMANS
INSTRUCTION MANUAL
REDPOST PU MONITOR
TYPE RPU-352/353
W W W.HAFFMANS.NL
W W W.HAFFMANS.NL

Advertisement

Table of Contents
loading

Summary of Contents for Pentair HAFFMANS RPU-352

  • Page 1 HAFFMANS HAFFMANS INSTRUCTION MANUAL REDPOST PU MONITOR TYPE RPU-352/353 W W W.HAFFMANS.NL W W W.HAFFMANS.NL...
  • Page 3 Essential reading! Haffmans BV is not responsible for any damage caused by the owner’s failure to follow the instructions given in this manual. Haffmans BV is not responsible for print or translation errors in this edition of the manual. The specifications and design of this product are subject of change without notice.
  • Page 5: Table Of Contents

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Table of contents Technical specifications Safety Symbols Precautions and safety instructions Installation Unpacking Operation Controls I/O switch Indicator Display illumination Switch functions and icons Auto power on Auto power off Low battery condition Starting Preparing the instrument Pressure zero setting Only for PRU-353...
  • Page 6 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 8.10 Time near maximum pressure Only for PRU-353 8.11 Reason for stopping Graph Cursor movement Graph lines Off-scale records Full List 10.1 Time line movement Battery Charging 11.1 Battery information 11.2 Battery temperature Menus 12.1...
  • Page 7 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Technical specifications Introduction Unpacking Control panel 21.1 Switching on 21.2 Connecting the monitor 21.3 Printing recorded files 21.4 After printing 21.4.1 200 Series P.U. monitors. 21.4.2 100 Series P.U. Monitors. Configuration settings 22.1 Clock setting 22.2...
  • Page 8 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 26.1 B-messages 26.2 C-messages 26.3 M-messages 26.4 P-messages 26.5 T-messages Back-up battery Instruction manual RPC-50, charger interface Technical specifications Unpacking Operating 30.1 Battery Charging 30.2 Connection to PC Safety Appendix I Background information Appendix II Diagrams Appendix III Customer service Appendix IV Terms of guarantee...
  • Page 9: Technical Specifications

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 1 TECHNICAL SPECIFICATIONS Storing data Max No. of files 4 * (a file is a single recording run) Max No. of fields 15860 (a field is one channel record) Recording timer setting 4 hours * (the maximum recording run) Recording interval setting...
  • Page 10 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Battery life From a fully charged battery Example (a) 2 maximum runs Record 4 hours, display (with backlight) 20 minutes Example (b) 15 typical runs Record 40 minutes, display (with backlight) 5 minutes Assumes final recording is completed within one week of the first Dimensions (Length x Width x Height)
  • Page 11: Safety

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 2 SAFETY 2.1 SYMBOLS Attention, warning and danger symbols used in this manual have the following significance. Attention! Information for correct or effective use of the equipment. Warning Incorrect or careless use can cause serious damage to the equipment.
  • Page 12 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 12 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 13: Installation

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 3 INSTALLATION 3.1 UNPACKING This manual was written for the RPU-352 and PRU-353. You will find all the information in this manual. When there is specific information for one product, it is written with the specific item. Before despatch the RPU-352, PRU-353 was checked and tested by Haffmans B.V.
  • Page 14 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 14 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 15: Operation

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 4 OPERATION 4.1 CONTROLS Flashing “ON” indicator Icon relates to this switch Display Icon DISPLAY There are four control switches arranged around the display screen. Operate the switches by touching one end of the actuator onto the glass in the marked area. Keep the actuator in position until you see a change in the display or the flashing indicator.
  • Page 16: Display Illumination

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 4.4 DISPLAY ILLUMINATION The I/O (on/off) switch also turns on the backlight that lights up the display. When any switch is operated or there is any other activity, such as connecting a probe, the backlight will turn on.
  • Page 17: Low Battery Condition

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 4.8 LOW BATTERY CONDITION If recording is taking place when the battery charge level falls below 15% then recording will stop and the file will be saved. This ensures that recordings cannot be corrupted by low battery condition. The results screen will show the reason for stopping.
  • Page 18 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 18 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 19: Starting

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 5 STARTING Temperature of probe (channel 1) Start recording Temperature of probe (channel 2) Only for PRU-353: Pressure (channel 3) Set pressure zero 5.1 PREPARING THE INSTRUMENT Switch on the instrument. If there are any problems, such as insufficient charge in the battery, the display will give the information you need.
  • Page 20 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Only for RPU-353: In order to make a record run the pressure sensor can be connected in the same bottle as the temperature sensor. Preparation for measurement in bottles and cans. For bottles an additional centre ring (1) is needed to centre the bottle.
  • Page 21: Pressure Zero Setting Only For Pru-353

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 5.2 PRESSURE ZERO SETTING Only for PRU-353 Before you connect the pressure fitting to the PRU-353 you should set the zero point of the pressure channel (channel 3). This setting should be made before each recording run and compensates for changes in atmospheric pressure.
  • Page 22 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 22 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 23: Recording

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 6 RECORDING Stop recording Animated indicator Only for PRU-353: Elapsed recording time The temperature of the probes, the pressure sensor reading and the elapsed recording time are shown on the display throughout the recording run. 6.1 STOPPING THE RECORDING When the instrument exits from the pasteuriser you can stop the recording by activating the top right switch ( ) or by unplugging either probe.
  • Page 24 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 24 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 25: Results

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 7 RESULTS The calculated results are displayed as soon as recording stops. It is also possible to select different representations of the results. 7.1 RESULTS DISPLAYS There are three different results displays and they can be selected from the main menu.
  • Page 26: Erasing A File

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 • The total PU value achieved (channel 1) • The unique ID number of the file • The total recording time (and optional date & time †) † If the instrument’s clock has been set then the date and time at the start of the recording is shown alternating with the total recording time.
  • Page 27: Calculated Results

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 8 CALCULATED RESULTS Shows the data in the recorded file reduced to the most important details. 8.1 TOTAL PU ACHIEVED The total number of Pasteurisation Units accumulated during the recording run. This is calculated using your chosen definition of PU and cut-off temperature.
  • Page 28: Temperature At Pasteuriser Exit

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 8.6 TEMPERATURE AT PASTEURISER EXIT The moment that the instrument leaves the pasteuriser is judged by a rise in light level from the relatively dark interior. Inspection lights inside the pasteuriser may prevent this result from being calculated.
  • Page 29: Graph

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 9 GRAPH This panel appears when cursor moves Flashing cursor PU cut-off temperature Return to menu screen Indicates that Indicates that graph graph extends Channel 1 Channel 2 extends to right to left Move cursor Move...
  • Page 30: Graph Lines

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 9.2 GRAPH LINES Channel 1 shows as a solid line on the graph while channel 2 shows as a dotted line. The position of the PU cut-off temperature is shown as a dashed line. The horizontal lines above each channel in the detailed record show the style of the line for that channel.
  • Page 31: Full List

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 10 FULL LIST Elapsed time from ONLY FOR Return to PRU-353 start of file Channel details menu screen Move line Move line to left to right “Time line” File ID number shows position in file Shows a list of all the data in the recorded file.
  • Page 32 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 32 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 33: Battery Charging

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 11 BATTERY CHARGING The battery in the instrument can be re-charged by the Redpost RPC-80 printer/charger or the Redpost RPC-50 battery charger. You can connect the charger to either socket. If you connect to the charger before recording a file you see the complete charging information on the screen.
  • Page 34 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 34 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 35: Menus

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 12 MENUS Select highlighted Highlighted item item Move highlight Move highlight down There are stages in the operation and configuration of the instrument when you need to choose an action etc. from a menu list. A menu shows all the possible choices or items in a vertical list.
  • Page 36 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 36 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 37: Key Plug (Configuration)

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 13 KEY PLUG (CONFIGURATION) The key plug is a special plug marked with a ‘K’ which can be inserted into either probe socket and puts the instrument into configuration mode. This allows you to change the way the instrument operates.
  • Page 38: Clock

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 13.4 CLOCK You can set the current date and time. Setting the clock in this way is optional. If recorded files are printed and then erased using the RPC-80 printer/charger then the clock settings of the RPC-80 will be automatically copied into the RPC-353.
  • Page 39: Active Channels

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 13.6 ACTIVE CHANNELS You can make the channels active or inactive using this screen. Inactive channels do not use up any storage memory and so longer recordings can be made if required. If you make a channel inactive in this way it will remain inactive for all recordings until you change the setting again using the key plug.
  • Page 40: Recording Interval

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 13.11 RECORDING INTERVAL This screen allows you to select the time interval between recordings. You can choose any value between 2 and 60 seconds. The factory setting is 10 seconds. 13.12 EQUIPMENT NUMBER This screen allows you to set your own equipment number or identification for the instrument.
  • Page 41: Output

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 14 OUTPUT The RPU-352, PRU-353instrument can be used as a stand-alone PU & pressure monitor or it can be connected to a variety of other equipment so that the recorded files can be permanently saved and/or printed. 14.1 STAND ALONE OPERATION With its detailed display of calculated results, graph and full list of all records it is possible to obtain all the information about a file directly from the display of the...
  • Page 42 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 42 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 43: Maintenance

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 MAINTENANCE General To maintain the accuracy and reliability of the equipment we recommend that it is serviced and re-calibrated (with the probes) at regular intervals. Under light conditions of use this should be carried out at least every 1500 recording runs. When the equipment is heavily used, particularly where high pasteuriser temperatures are involved as with fruit juices, then the service and re-calibration should take place every year.
  • Page 44 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Battery Always switch the instrument off when it is not in use. If the instrument is left idle it will switch off automatically. Do not leave the battery on charge continuously for more than 24 hours. If the equipment has not been returned for servicing as recommended above then as the battery ages it will not hold as much charge as it did when new.
  • Page 45: Frequently Asked Questions

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 16 FREQUENTLY ASKED QUESTIONS Battery 1) Sometimes the battery charge indicator doesn’t move even though the instrument is connected to the charger. What’s wrong? 2) When I switch the instrument on it often has less charge in it than when I switched it off. Why? 3) How long should I leave the instrument connected to the charger? 4) How long will the battery last?
  • Page 46 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 2) When I switch the instrument on it often has less charge in it than when I switched it off. Why? When the instrument is switched off and left unused the battery gradually loses charge by a process known as “self discharge”.
  • Page 47: Controls

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 In your case the instrument has wrongly sensed a battery change. You should follow the instructions on the display and charge the battery as if it were new. The internal clock settings and any saved files will have been lost.
  • Page 48: Results

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 16.3 RESULTS 10) If the product temperature is exactly equal to the cut-off temperature will any PU’s be achieved? Yes, PU’s will be achieved and added to the total. The precise definition of the PU cut-off (see “Results”...
  • Page 49 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 updated every time files are printed out and then erased. (The software in the RPC-80 must be version ‘p’ or later.) This makes it easy to maintain a plant-wide standard for date & time without making modifications to all the monitors.
  • Page 50: Haffmans Rpu 352, Rpu 353, Rpc 80 Rpc

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 50 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 51: Instruction Manual Rpc-80 Printer/Charger

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 INSTRUCTION MANUAL RPC-80 PRINTER/CHARGER Essential reading!
  • Page 52 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50...
  • Page 53: Technical Specifications

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 TECHNICAL SPECIFICATIONS Voltage 82-275V, 50/60Hz Dimensions (LxWxH) 310x240x150 mm Weight 4,5 kg Charging time 6 hours for full charge (300 serie) Display LCD, back illuminated, 2 lines, 24 characters Outputs USB for printing RS-232 RPU 352, RPU 353, RPC 80, RPC 50 Page 53 of 112...
  • Page 54 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 54 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 55: Introduction

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 INTRODUCTION The RPC-80 converts the data from the RPU.-351, RPU-352 and RPU-353 into an easy to understand tabulated result that is printed on a separate printer by just pressing one button. Furthermore the data can be passed on to a computer.
  • Page 56 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 56 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 57: Unpacking

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 UNPACKING Before despatch the PRU-352 / RPU-353 was checked and tested by Haffmans BV. Make sure that the content of the delivery is complete and undamaged. If the delivery is incomplete or damaged, please contact Haffmans BV or the representative/agent designated by Haffmans BV, immediately (appendix IV).
  • Page 58 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 • Page 58 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 59: Control Panel

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 CONTROL PANEL Warning Before using the RPC-80 first carefully read this chapter 2 Line display 3 Switches Haffmans-REDPOST RPC-80 Fig. 20.1 Control panel RPU 352, RPU 353, RPC 80, RPC 50 Page 59 of 112...
  • Page 60 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 60 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 61: Use

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Warning Read this chapter carefully before using the RPC-80. The RPC-80 is not waterproof. 21.1 SWITCHING ON Switch on the mains switch of the RPC-80. The display will light up and briefly show time and date.
  • Page 62: Printing Recorded Files

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 21.3 PRINTING RECORDED FILES ATTENTION Do not switch the P.U. Monitor off until all printing has been completed. Leave the P.U. monitor connected to the printer charger until the required charging time is over. "FOUND...", When a monitor has been connected the display changes to and the monitor...
  • Page 63: Configuration Settings

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 CONFIGURATION SETTINGS When you first switch on the RPC-80 an introductory display of time and date is shown for about 5 seconds. If you hold any of the control buttons in until this display finishes you will enter the setting section.
  • Page 64 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 64 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 65: Configuration Menu Section

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 23 CONFIGURATION MENU SECTION The configuration section is protected by a simple password system that is designed to prevent inadvertent operation. To enter the configuration section, first enter the setting section in the normal way by switching on and holding down any button until the operating display of time and SET CLOCK RESET DATE AND TIME...
  • Page 66: Calculation Set-Up

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Head space correction The RPU-353 use a pressure sensor inside the instrument that connects to the container via a quick release coupling and a fine flexible tube. This causes a slight increase in volume. If the theoretical volume of the head space of the container is known and entered into the RPC-80 then the unit can make a first order correction for the error.
  • Page 67: Template Set-Up

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Dual channel monitors It is possible to set up different P.U. Cut-off temperatures for channel 1 and channel 2 on dual P.U. ON CHANNEL 2 channel monitors. With it is possible to turn off the P.U. calculation on channel 2.
  • Page 68: Template Recording

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 23.3.1 TEMPLATE RECORDING When template recording is switched on the operator will be given the choice to record each run as a template after it has been printed out. Each template takes a number and when you record a new template the template number that is first offered is the lowest free template number.
  • Page 69: Template Exchange

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Degree of fit to template The degree of fit to the selected template is printed in the results. The comparison starts when both traces pass through the P.U. Cut-off temperature for the first time and stops when the shortest trace ends, see table 7.1.
  • Page 70: Editing A Template Name

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 23.5 EDITING A TEMPLATE NAME Edit Template ID in the template set-up menu allows you to change a template name at any time after it has been recorded or imported. Select the template name you wish to change and then edit the name in the normal way.
  • Page 71: Full List Set-Up

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 RPC-80 ID set-up Each RPC-80 can be given its own identification. Press OK to start when the display introduces SET RPC-80 ID. Set up the ID as required. The ID can have up to 15 characters (letters or numbers).
  • Page 72: External Link Set-Up

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 23.10 EXTERNAL LINK SET-UP The External Link menu allows you to set the serial format for communications on the link. These must be set up to match the serial format of the external computer connected to the external link.
  • Page 73: Finished Set-Up : Exit

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Soft Handshake In the Soft Handshake system the handshaking is managed without extra signal connections by sending handshake characters mixed in with the data characters. These handshake characters are known as "XOn" and "XOff". During Soft Handshake the signals used for Hard Handshake should not be used.
  • Page 74 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 74 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 75: Printed Results

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 24 PRINTED RESULTS The RPC-80 printer/charger unit can print out the results of the P.U. monitors together with a graphical representation of the recorded data. Several sample sections of printed results are shown below.
  • Page 76 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 76 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 77: System Errors

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 25 SYSTEM ERRORS Warning Only qualified persons should attempt to repair electronics, When equipment is under guarantee it must in all cases be returned for repair or replacement if faults occur. 25.1 SYSTEM ERROR 02 &...
  • Page 78 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 78 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 79: Faulty Operation

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 26 FAULTY OPERATION Sometimes an error will occur that prevents the RPC-80 playback unit from completing an SEE MANUAL operation. When this happens the display will show a message followed by PAGE...
  • Page 80 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 ATTENTION! Never unplug this lead until the "Printing Finished" message shows and the charge rate has reduced to trickle charge. It is possible that an error could be caused by very severe interference from other nearby equipment or on the mains wiring.
  • Page 81: M-Messages

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 There has been an error in the communications between the RCP-80 and an external computer on the External link. • The lead that connects the external computer to the RPC-80 may have become "Data Transfer..."...
  • Page 82: P-Messages

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 ATTENTION! Enter the correct time and date that the back-up battery was fitted followed by the serial number of the instrument. Until these items have been correctly entered the fault will recur on each power up. The memory that stores the recorded templates for the RPC-80 has become corrupted and all the data in it has been lost.
  • Page 83: T-Messages

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 26.5 T-MESSAGES All messages starting with a “T” are messages concerning the templates. The recording of the template selected for use has been damaged in some way and it cannot be used.
  • Page 84 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 This recording run can't be saved as a template. In order to save a recording run as a template the following conditions must all be met: • Channel 1 must have been active in the P.U. monitor. •...
  • Page 85: Back-Up Battery

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 BACK-UP BATTERY This small back-up battery maintains the clock and calendar functions and saves the templates while the mains power to the RPC-80 is switched off. The battery should last approximately seven years but we recommend that you replace it every five years.
  • Page 86 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 86 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 87: Instruction Manual Rpc-50, Charger Interface

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 INSTRUCTION MANUAL RPC-50, CHARGER INTERFACE Essential reading!
  • Page 88 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50...
  • Page 89: Technical Specifications

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 28 TECHNICAL SPECIFICATIONS Voltage 100-240V 47/63Hz Dimensions (LxWxH) 190x130x105 mm Weight 530g Charging time 4 hours for full charge Display No display Outputs Power supply RS-232 Charger RPU-120+, RPU 351, RPU-352, RPU-353 RPU 352, RPU 353, RPC 80, RPC 50 Page 89 of 112...
  • Page 90 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 90 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 91: Unpacking

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 29 UNPACKING Before despatch the RPC-50 was checked and tested by Haffmans B.V. Make sure that the content of the delivery is complete and undamaged. If the delivery is incomplete or damaged, please contact Haffmans B.V. or the representative/agent designated by Haffmans B.V, immediately (appendix IV).
  • Page 92 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 92 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 93: Operating

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 OPERATING 30.1 BATTERY CHARGING The RPC-50 is designed to recharge the battery of the PU monitor type PRU-352 / RPU-353. As soon as you connect the RPC-50 to the mains it is ready for use. Refer to the operating manual of the PRU-352 / RPU-353 for complete information about charging the battery.
  • Page 94 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 94 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 95: Safety

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 31 SAFETY Always follow basic safety precautions when using this equipment to reduce risk of injury. Before using the equipment, read and understand the operating instructions in this manual. This equipment is intended to recharge the battery in the PRU-352 / RPU-353 PU Monitor and to connect the PRU-352 / RPU-353 to a personal computer.
  • Page 96 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 96 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 97: Appendix I Background Information

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 APPENDIX I BACKGROUND INFORMATION PU calculation The Pasteurisation Unit (PU) is defined as relating to the sterilising effect observed when the product is held for one minute at a temperature termed the Base value.
  • Page 98 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Temperature Probe position It is generally accepted that a slow circulation takes place in the beverage container, driven by the temperature difference between the hot container wall and the cooler body of liquid inside. This implies that the product will not be well mixed in the container during pasteurisation and so we must assume that there will be variations in the treatment received between individual contaminant cells and micro-organisms.
  • Page 99: Appendix Ii Diagrams

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 APPENDIX II DIAGRAMS BASICS NORMAL OPERATION CONFIGURATION PREPARE INSERT KEY PLUG FIT PROBES Language Display contrast ZERO PRESSURE Clock Display Units Active channels PU calculation Recording Interval RECORDING Equipment number Mains frequency VIEW RESULTS VIEW GRAPH OUTPUT...
  • Page 100 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 100 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 101: Appendix Iii Customer Service

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 APPENDIX III CUSTOMER SERVICE Warning Repairs to the electrical parts of the RPU-352, PRU-353 should always be carried out by a Haffmans service engineer. The trouble shooting chart list a number of potential minor problems and indicates how the customer can solve these problems.
  • Page 102 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 102 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 103: Appendix Iv Terms Of Guarantee

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 APPENDIX IV TERMS OF GUARANTEE This Haffmans guarantee is in addition to all the rights accruing to the buyer from the sales contract between buyer and supplier and the relevant legislation. Haffmans BV guarantees that the equipment supplied is free from material and manufacturing defects, for normal use and maintenance.
  • Page 104 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 104 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 105: Appendix V Ec Declaration Of Conformity Rpu 352 / 353

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 APPENDIX V EC DECLARATION OF CONFORMITY RPU 352 / 353 ORIGINAL EC DECLARATION OF CONFORMITY EC DECLARATION OF CONFORMITY HAFFMANS B.V. Marinus Dammeweg 30 5928 PW Venlo, Holland declare entirely under our own responsibility, that the product PU MONITOR, TYPE RPU 352 / 353 upon this statement has reference to, is in conformity with the norms EN 61000-6-2, EN 61000-6-3, EN 60825-1.
  • Page 106 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 106 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 107: Appendix Vi Ec Declaration Of Conformity Rpc 50

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 APPENDIX VI EC DECLARATION OF CONFORMITY RPC 50 TRANSLATION OF THE ORIGINAL EC DECLARATION OF CONFORMITY EC DECLARATION OF CONFORMITY HAFFMANS B.V. Marinus Dammeweg 30 5928 PW Venlo, Holland declare entirely under our own responsibility, that the product CHARGER INTERFACE, TYPE RPC 50 upon this statement has reference to, is in conformity with the norms EN 60950-1, EN 61000-6-2, EN 61000-6-3...
  • Page 108 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 108 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 109: Appendix Vii Ec Declaration Of Conformity Rpc 80

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 APPENDIX VII EC DECLARATION OF CONFORMITY RPC 80 TRANSLATION OF THE ORIGINAL EC DECLARATION OF CONFORMITY EC DECLARATION OF CONFORMITY HAFFMANS B.V. Marinus Dammeweg 30 5928 PW Venlo, Holland declare entirely under our own responsibility, that the product PRINTER / CHARGER, TYPE RPC 80 upon this statement has reference to, is in conformity with the norms EN 55022, EN 60950-1, EN 61000-6-1...
  • Page 110 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 Page 110 of 112 RPU 352, RPU 353, RPC 80, RPC 50...
  • Page 111: Appendix Viii Spare Parts

    HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 APPENDIX VIII SPARE PARTS When you order spare parts please include all the following information with your order: • Serial number of the RPU-352, PRU-353. • Position number (on the parts list below). •...
  • Page 112 HAFFMANS RPU 352, RPU 353, RPC 80 RPC 50 353 Temperature probe Lg 270 mm 107.031 353 Temperature probe Lg 310 mm 107.039 353 Temperature probe Lg 350 mm 107.027 352 Plate with bottle holder Ø 45-55 mm 001.650 352Plate with bottle holder Ø 55-68 mm 002.214 352 Plate with bottle holder Ø...

This manual is also suitable for:

Haffmans rpu-353

Table of Contents