Extron electronics ISS 608 User Manual page 16

Seamless switchers true seamless 4k/60 hdmi and displayport switcher
Hide thumbs Also See for ISS 608:
Table of Contents

Advertisement

ATTENTION:
Mode Activation
1
Hold in the recessed rear
panel Reset button while
applying power to the unit.
NOTE: Do not operate with the default firmware loaded by a mode 1 reset. Use it only to load the
most current firmware to the device.
*4
Hold in the Reset button until
the Reset LED blinks twice
(once at 3 seconds, again
at 6 seconds). Then, release
and press the Reset button
again within 1 second*.
*5
Hold in the Reset button until
the Reset LED blinks three
times (once at 3 seconds,
again at 6 seconds, again
at 9 seconds). Then, release
and press the Reset button
again within 1 second*.
NOTES:
*For modes 4 and 5, nothing happens if the momentary press does not occur within 1 second.
The factory configured passwords for all accounts on this device have been set to the device serial
number. In the event of a complete system reset, the passwords convert to the default, which is no
password (see
Passwords
Review the reset modes carefully. Some reset modes delete all user loaded
content and revert the device to default configuration.
Analysez minutieusement les différents modes de réinitialisation. Certains
modes de réinitialisation suppriment l'intégralité du contenu chargé de
l'utilisateur et remettent l'appareil au mode de configuration par défaut.
ISS 608 Reset Modes
Result
The ISS 608 reverts to the factory
default firmware for a single power
cycle.
Sets port mapping back to factory
default.
Sets the IP address
back to factory default
(192.168.254.254).
Sets the subnet mask address
back to the factory default
(255.255.255.0).
Sets the gateway IP address to
the factory default (0.0.0.0).
Turns DHCP off.
The Reset LED on the rear panel
of the unit flashes four times in
succession.
Performs a complete reset to factory
defaults (except the firmware).
Does everything mode 4 does.
Clears port configurations.
Resets all IP options.
Clears all user settings.
Clears all files from the unit.
The Reset LED on the rear panel
of the unit flashes four times in
succession.
on page 57 to change a password).
Purpose and Notes
Use mode 1 to revert to
the factory default firmware
for a single power cycle if
incompatibility issues arise
with user-loaded firmware.
All user files and settings are
maintained.
Mode 4 is used to set
IP address information using
ARP and the MAC address.
Resetting IP Settings
appears on a connected
display.
Mode 5 is useful to start over
with default configuration and
uploading, and also to replace
events.
Resetting ISS 608 appears
on a connected display.
Mode 5 is equivalent to
SIS command ZQQQ (see
SIS command
page 55).