2Nd And 3Rd Mirror Removal - Ricoh Robin Service Manual

Table of Contents

Advertisement

OPTICS

2.3 2ND AND 3RD MIRROR REMOVAL

[A]
[D]
1. Turn off the main switch.
2. Remove the exposure glass. (See Exposure Glass Removal.)
3. Slide the 1st scanner two thirds of the way to the right.
4. Remove the front spring plate [A] of the 2nd mirror [B].
5. Carefully shift the 2nd mirror toward the front of the machine to remove
the rear spring plate [C].
6. Lift the 2nd mirror out of the machine.
7. Remove the pulley bracket [D] of the exposure lamp harness [E]
(1 screw).
8. Remove the 3rd mirror [F] in the same way as the 2nd mirror.
[B]
[E]
5-8
24 June 1994
[C]
[F]