X482 Analog inputs/outputs
Table 9- 17
Terminal block X482
Terminal
1
2
3
4
5
6
7
8
Max. connectable cross-section: 0.5 mm
AI: analog input, AO: Analog output
1)
Note
Permissible voltage values
In order to avoid incorrect results of the analog-digital conversion, the analog differential
voltage signals can have a maximum offset voltage of +/-30 V with respect to ground
potential.
Note
Open input
An open input is interpreted as approximately "0 V".
The power supply of the analog inputs/outputs is drawn via the option slot of the Control Unit
and not via X424.
The shield is connected to the Control Unit.
Cabinet Modules liquid cooled
Manual, 10/2015, A5E37067587A
Designation
1)
AI 0+
AI 0-
AI 1+
AI 1-
AO 0+
AO 0-
AO 1+
AO 1-
2
Technical data
Analog inputs (AI)
Voltage: -10 ... +10 V; R
: 65 kΩ
i
Common mode range: ±30 V
Resolution: 13 bits + sign
Analog outputs (AO)
Voltage range: -10 ... +10 V
Load current: max. -3 ... +3 mA
Resolution: 11 bit + signed
Continuous short-circuit proof