Setting Terminal Parameters; Powering On The Switch - H3C S6820 Series Installation Manual

Hide thumbs Also See for S6820 Series:
Table of Contents

Advertisement

Figure 48 Completing the device driver installation wizard

Setting terminal parameters

To configure and manage the switch through the console port, you must run a terminal emulator
program, TeraTermPro or PuTTY, on your configuration terminal. You can use the emulator program
to connect a network device, a Telnet site, or an SSH site. For more information about the terminal
emulator programs, see the user guides for these programs
The following are the required terminal settings:
Bits per second—9600.
Data bits—8.
Stop bits—1.
Parity—None.
Flow control—None.

Powering on the switch

Before powering on the switch, verify that the following conditions are met:
1.
All the fan tray slots have a fan tray installed.
The power cords are connected correctly.
The input power voltage is as required by the switch.
The console cable is connected correctly.
The configuration terminal (a PC, for example) has started, and its serial port settings are
consistent with the console port settings on the switch.
31