Grounding the switch

CAUTION:
• Correctly connecting the grounding cable is crucial to lightning protection and EMI protection.
• Do not connect the grounding cable to a fire main or lightning rod.
• To guarantee the grounding effect and avoid switch damage, use the grounding cable provided
with the switch to connect the switch to a grounding strip in the equipment room.
The power input end of the switch has a noise filter, whose central ground is directly connected to the
chassis to form the chassis ground (commonly known as PGND). You must securely connect this
chassis ground to the earth so the faradism and leakage electricity can be safely released to the
earth to minimize EMI susceptibility of the switch.
To ground the switch:
As shown in
1.
point on the chassis. For more information, see
chassis."
The grounding point in
Remove the hex nut of a grounding post on the grounding strip.
2.
Attach the ring terminal of the grounding cable to the grounding post on the grounding strip, and
3.
secure the ring terminal to the grounding post with the hex nut.
Figure 27
and
Figure 28
Figure 29,
attach the two-hole grounding lug of the grounding cable to a grounding
Figure 29
is for illustration only.
are for illustration only.
"Connecting the grounding cable to the