Operation Range And Main Specifications; Operation Range; Main Specifications - Daikin LX10F11B3 Service Manual

Inverter container refrigeration unit, decos va
Table of Contents

Advertisement

https://daikin-p.ru

5.1 Operation Range and Main Specifications

5.1.1 Operation Range

Use this unit within the following ranges.
Item
Ambient temperature range
Inside temperature range
Temperature
Cooling water
Water volume
Water pressure
Voltage
Vibration/impact

5.1.2 Main Specifications

Item
Chilled mode
Mode Switch
Frozen mode
Condenser cooling system
Controller
Inverter compressor
Evaporator
Air cooling condenser
Water-cooled condenser
Evaporator fan
Evaporator fan motor
Condenser fan
Condenser fan motor
Defrosting system
Refrigerant control
Capacity control
Refrigerant
Refrigerant oil
Weight
Operation Range
+50℃〜-30℃(+122℉〜-22℉)
+30℃〜-30℃(+86℉〜-22℉)
+36℃〜+10℃(+96.8℉〜+50℉)
23〜30L/min
196〜490kPa(2〜5kg/cm
50Hz:380 / 400 / 415V
60Hz:440 / 460V
Voltage fluctuation rate±10%
Horizontal direction: 5G, vertical direction: 2G
Main Specifications
+30.0℃ 〜 -9.9℃ (+86.0℉ 〜 +14.1℉)
-10.0℃ 〜 -30.0℃ (+14.0℉ 〜 -22.0℉)
Air/Water-Cooled Type
DECOSVa
Hermetically sealed scroll type (Rated motor output 3.75kW,
MAX. motor output 8.1kW)
Cross-fin coil type
Cross-fin coil type
Shell-and-tube type
Propeller fan
Squirrel-cage three phase induction motor (Motor output:
400W/60W), dual speed, 2P/4P
Propeller fan
Squirrel-cage three phase induction motor (Motor output:
670W/120W), dual speed, 4P/6P
Hot-gas defrosting system
Electronic expansion valve
By inverter compressor and hot-gas control
R134a (For refrigerant charging amount, refer to the name plate)
IDEMITSU, Daphne hermetic oil FVC68D
For detail, refer to the name plate, unit performance
5-2