Troubleshooting - Jackson CONSERVER XL-E Installation, Operation And Service Manual

Dishmachines
Table of Contents

Advertisement

TROUBLESHOOTING

OBSERVATION
Machine will not run,
no voltage at wash relay
terminals L1 and T1.
Machine will not run in "ON"
position or in Delime mode.
Machine fills continuously
even with no power
applied to the machine.
Machine runs
continuously in the
wash cycle.
Machine will not
hold water.
Machine will not fill,
other functions work.
07610-003-92-84-R
POSSIBLE CAUSE
1. Service disconnect switch
off or faulty.
2. Branch circuit breaker
tripped/fuse blown.
3. Loose or broken connection
to machine.
1. Door switch is defective.
2. Faulty OFF/ON/FILL switch.
3. Faulty NORMAL/DELIME
switch.
Water inlet solenoid valve
allowing water into machine.
1. Machine is in Delime mode.
2. Possible issue with CAM timer.
1. Faulty drain ball.
2. Obstructed drain hole.
3. Drain linkage is binding.
1. Y-strainer clogged.
2. Incoming water to machine is
turned off.
3. Faulty OFF/ON/FILL switch.
4. Faulty solenoid coil.
TROUBLESHOOTING
REMEDY
1. Turn disconnect on.
2. Reset or replace.
3. Tighten or replace connections.
1. With door open, check for voltage between
ORANGE/WHITE door switch and neutral.
If 120 V, replace the door switch.
2. With switch ON, check voltage between BLACK
and WHITE/BLACK wires to switch. Replace the
switch if 120 V.
3. In the NORMAL position, check the voltage between
WHITE/BLACK and WHITE/RED wires to switch.
If 120 V, replace the switch.
1. Check water pressure during fill, pressure must
be 15 PSI.
2. Repair or replace water inlet solenoid valve.
1. Flip NORMAL/DELIME switch to NORMAL mode.
2. Contact the manufacturer.
1. Replace drain ball.
2. Clear obstruction from drain.
3. Repair damaged drain mechanism parts.
1. Clean strainer screen.
2. Turn on water to the machine.
3. Depress switch, measure between BLACK and
WHITE/GREEN wires. If 120 V, replace switch.
4. If coil has voltage but no continuity, replace solenoid.
22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Conserver xl-elthConserver xl hh

Table of Contents