Voltage Check; Preparing Chemical Feeder Pumps; Priming Chemical Feeder Pumps - Jackson CONSERVER XL-E Installation, Operation And Service Manual

Dishmachines
Table of Contents

Advertisement

INSTALLATION

VOLTAGE CHECK

!
CAUTION
i
PREPARING
CHEMICAL FEEDER
PUMPS
!
CAUTION
PRIMING CHEMICAL
FEEDER PUMPS
!
CAUTION
07610-003-92-84-R
1. Ensure power switch is in the OFF position and apply power to the
2. Check the incoming power at terminal block and ensure it corresponds to voltage
listed on the data plate. If not, contact a qualified service agency to examine the
problem.
CAUTION! Do not run the
electrical codes).
3. Shut off the service breaker and mark it as being for the
4. Advise all proper personnel of any problems and of the location of the service
breaker. Replace control box cover.
These
s are supplied with detergent, rinse-aid, and sanitizer chemical feeder
machine
pumps.
Locate open ends of chemical tubes with the stiffeners and place each one in the
appropriate container.
• Red Tubing = Detergent
• White Tubing = Sanitizer
CAUTION! Chlorine-based sanitizers can be detrimental to this machine if the chemical
solution is too strong. Contact chemical supplier to ensure the dispenser is set-up
correctly.
Chemical feeder pumps need priming when the machine is first installed or if the
chemical lines have been removed and air was allowed to enter.
CAUTION! Water must be in the sump and wash tank before chemicals are dispensed.
1. Verify proper chemical tube with stiffener is in the proper container.
2. Use toggle switches on front of control box to prime each pump. There are three
priming switches:
3. To prime the pumps, hold the switch in the momentary position until the
chemical is seen entering the sump.
Detergent:
INSTRUCTIONS
if voltage is too high or too low (refer to applicable
machine
• Blue Tubing = Rinse-aid
.
machine
.
machine
11