B. Wiring Requirements
IntelliFire Touch
Ignition System Wiring
®
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.2, IntelliFire Touch (IPI) Wiring Diagram.
• This appliance is equipped with an IntelliFire control valve
which operates on a 6 volt system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
IFT-RC400
REMOTE
CONTROL
IFT-RC150
WIRELESS
WALL SWITCH
(OPTIONAL)
RF MODULE
ORANGE
(PILOT)
APPLIANCE
(OPTIONAL)
Figure 8.2 IntelliFire Touch Wiring Diagram
50
Heat & Glo • SL-3X-IFT, SL-5X-IFT, SL-7X-IFT, SL-9X-IFT Installation Manual • 2472-980 Rev. Q • 3/20
FLAME
TO JUNCTION
IGNITER
SENSE
BOX (110-120 VAC)
WHITE
ORANGE
AUXILIARY CONTROL
ELECTRONIC CONTROL
MODULE (ACM)
MODULE (ECM)
FLAME
MODULATION
GREEN
(MAIN)
RED
BLK (GROUND)
BLK
BRN
ON/OFF
CONTROL
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
LED's
LED's are factory installed.
maintenance is required.
TO JUNCTION
BOX (110-120 VAC)
FAN
LED
CONTROL
NOT USED FOR SL-3X-IFT, SL-5X-IFT, SL-5XLP-IFT,
SL-7X-IFT, SL-7XLP-IFT, SL-9X-IFT MODELS
6V DC
MODELS.
BATTERY PACK
RED
BLK
No additional set up or
(OPTIONAL POWER VENT)
PVLP-SLP
PVI-SLP-B
WIRE HARNESS
PVI-WH10
PVI-WH20
PVI-WH40
PVI-WH60
PVI-WH80
PVI-WH100
EMBER LIGHTING

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl-5x-iftSl-5xlp-iftSl-7x-iftSl-7xlp-iftSl-9x-ift

Table of Contents