2 SCREWS
Figure 6.7 To attach the first section of vent pipe, make
sure to use the fiberglass gasket to seal between the first
vent component and the outer fireplace wrap. Use 2 self
tapping screws to secure the gasket to the outer wrap.
Note: Once the seal cap has been removed, it cannot be
reattached.
Rear Vent
NOTICE: Once appliance is set up for top or rear venting,
it CANNOT be changed at a later time.
Figure 6.8
(Generic Fireplace Shown) Fold the tabs
toward the center of the fire plug (90º) and remove the
insulation gasket.
Figure 6.9 (Generic Fireplace Shown) Cut the metal
retaining band and fold the sides out.
40
Heat & Glo • SL-3X-IFT, SL-5X-IFT, SL-7X-IFT, SL-9X-IFT Installation Manual • 2472-980 Rev. Q • 3/20
NOTICE: Once the seal cap has been removed it CANNOT
be reattached.
Figure 6.10 (Generic Fireplace Shown) Fold the center
parts of the retaining band out and use to remove the seal
cap.
Figure 6.11 (Generic Fireplace Shown) Discard the seal
cap, remove and discard the insulation basket. Note: Once
the seal cap has been removed it CANNOT be reattached.
Figure 6.12 (Generic Fireplace Shown) Attach the first
vent section (it will snap into place). Slide the insulation
gasket onto the vent section, up against the appliance
and over the tabs. Use two self-tapping screws to secure
gasket to outer wrap.