Wiring Requirements - Heat & Glo SL-5F-IFT Installation Manual

Hide thumbs Also See for SL-5F-IFT:
Table of Contents

Advertisement

B. Wiring Requirements
IntelliFire
Touch Ignition System Wiring
®
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.3 IntelliFire Touch (IFT) Wiring Diagram.
• This appliance is equipped with an IntelliFire control valve
which operates on a 6 volt system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the appliance OR install 4 AA cell
batteries (not included) into the battery pack before use.
IFT-RC400
REMOTE
CONTROL
(OPTIONAL)
IFT-WFM
WIFI MODULE
(OPTIONAL)
WIFI MODULE
RF MODULE
IFT-RC150
WIRELESS
WALL SWITCH
(OPTIONAL)
Figure 8.3 IntelliFire Touch Ignition Wiring Diagram
TO JUNCTION
FLAME
BOX (110-120 VAC)
IGNITER
SENSE
WHITE
ORANGE
AUXILIARY CONTROL
ELECTRONIC CONTROL
MODULE (ACM)
MODULE (ECM)
FLAME
MODULATION
GREEN
ORANGE
(MAIN)
(PILOT)
RED
BLK (GROUND)
APPLIANCE
BLK
BRN
ON/OFF
CONTROL
(OPTIONAL)
Heat & Glo • SL-5F-IFT, SL-7F-IFT Installation Manual • 2638-980 Rev. H • 6/22
NOTICE: Batteries should only be used as a power
source in the event of an emergency power outage.
Batteries should not be used as a primary long-term power
source. Batteries tend to corrode over time. When using
batteries as a power source, the 6 volt transformer must
be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
TO JUNCTION
BOX (110-120 VAC)
FAN
(OPTIONAL)
6V DC
MODELS.
BATTERY PACK
RED
BLK
(OPTIONAL POWER VENT)
PVLP-SLP
PVI-SLP-B
PVV-SLP
WIRE HARNESS
PVI-WH10
PVI-WH20
PVI-WH40
PVI-WH60
PVI-WH80
PVI-WH100
51