Top Vent - Horizontal Termination - (continued)
Two Elbows
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when
using flex vent except when
using the simple up and out
installation. See Figure 4.9.
WARNING *
Fire Risk.
• When using SLP-HRC-SS termination cap
on top vented fireplaces, a one foot minimum
vertical vent section is required before installing
first elbow.
H
Figure 4.12
Heat & Glo • SL-3X-IFT, SL-5X-IFT, SL-7X-IFT, SL-9X-IFT Installation Manual • 2472-980 Rev. Q • 3/20
1/2 ft.*
1-1/2 ft.*
2-1/2 ft.*
3-1/2 ft.
4-1/2 ft.
2
INSTALLED
HORIZONTALLY
V Minimum
90º Elbow*
152 mm
457 mm
762 mm
1.1 m
1.4 m
H
+ H
Maximum= 14 ft. (4.3 m)
1
2
V
+ H
+ H
Maximum= 40 ft. (12.2 m)
1
1
2
* See warning below
H
1
H Maximum
All Models
NOT ALLOWED
1 ft.
305 mm
2 ft.
610 mm
4 ft.
1.2 m
6 ft
1.8 m
14 ft.
4.3 m
V
1
23