Commissioning
4.2 Further settings
P-No.
Note
p2240
Techn. controller motorized potentiometer start
value [%]
r2245
CO: Techn. controller motorized potentiometer
setpoint before RFG [100 ≙ 100%]
p2247
Techn. controller motorized potentiometer ramp-
up time [s]
p2248
Techn. controller motorized potentiometer ramp-
down time [s]
r2250
CO: Techn. controller motorized potentiometer
setpoint after RFG [100 ≙ 100%]
p2251
Techn. controller mode
0
Techn. controller as main speed setpoint
1
Techn. controller as additional speed
setpoint
p2253
CI: Techn. controller setpoint 1 [100 ≙ 100%]
p2254
CI: Techn. controller setpoint 2 [100 ≙ 100%]
p2255
Techn. controller setpoint 1 scaling [100 ≙ 100%]
p2256
Techn. controller setpoint 2 scaling [100 ≙ 100%]
p2257
Techn. controller ramp-up time [s]
p2258
Techn. controller ramp-down time [s]
r2260
CO: Techn. controller setpoint after ramp function
generator [100 ≙ 100%]
p2261
Techn. controller setpoint filter time constant [s]
p2263
Techn. controller type
0
D component in the actual value signal
1
D component in the fault signal
p2264
CI: Techn. controller actual value [100 ≙ 100%]
p2265
Techn. controller actual value filter time constant
[s]
r2266
CO: Techn. controller actual value after filter [100
≙ 100%]
p2267
Techn. controller upper limit actual value [100 ≙
100%]
p2268
Techn. controller lower limit actual value [100 ≙
100%]
p2269
Techn. controller gain actual value [%]
p2270
Techn. controller actual value function selection
0
No function
2
p2271
Techn. controller actual value inversion (sensor
type)
0
No inversion
1
Inversion of the technology controller actual
value signal
38
P-No.
r2272
r2273
p2274
p2280
p2285
p2286
p2289
p2291
p2292
p2293
r2294
p2295
p2296
p2297
p2298
p2299
p2302
p2306
r2344
p2345
r2349
p2900
p2901
r2902
1
√x
p2930
3
r3113
p3320
Note
CO: Techn. controller actual value scaled [100 ≙
100%]
CO: Techn. controller error [100 ≙ 100%]
Techn. controller actual differentiation time
constant [s]
Techn. controller proportional gain
Techn. controller integral time [s]
BI: Hold techn. controller integrator
CI: Techn. controller pre-control signal [100 ≙
100%]
CO: Techn. controller maximum limit [100 ≙
100%]
CO: Techn. controller minimum limit [100 ≙ 100%]
Techn. controller ramp-up/ramp-down time [s]
CO: Techn. controller output signal [100 ≙ 100%]
CO: Techn. controller output scaling [100 ≙
100%]
CI: Techn. controller output scaling [100 ≙ 100%]
CI: Techn. controller maximum limit signal source
[100 ≙ 100%]
CI: Techn. controller minimum limit signal source
[100 ≙ 100%]
CI: Techn. controller limit offset [100 ≙ 100%]
Techn. controller output signal start value [%]
Techn. controller fault signal inversion
0
No inversion
1
Inversion of the techn. controller fault signal
CO: Techn. controller last speed setpoint
(smoothed) [100 ≙ 100%]
Techn. controller fault response
0
Function inhibited
1
For a fault: change over to r2344 (or p2302)
2
For a fault: Change over to p2215
CO/BO: Techn. controller status word
CO: Fixed value 1 [100 ≙ 100%]
CO: Fixed value 2 [100 ≙ 100%]
CO: Fixed values [100 ≙ 100%]
CO: Fixed value M [Nm]
CO/BO: NAMUR message bit bar
Fluid flow machine P = f(n), Y coordinate: P flow
1%, point 1
SINAMICS G120C frequency converter
Getting Started, 03/2012, FW V4.5, A5E03831830B AA