Wiring the terminal strip
Wiring variants
Wiring using the internal power supply
Wiring using an external power supply
Wiring using the internal power supply
Wiring using an external power supply
Permissible cable cross-section:
Recommended cable cross section:
EMC-compliant installation
● Use shielded cables for connecting the terminal strip to other components.
● Use a clamp for connecting the shielded cable. Connect the shield to the mounting plate
SINAMICS G120C frequency converter
Getting Started, 03/2012, FW V4.5, A5E03831830B AA
or to the shield plate through a good electrical connection and through the largest
possible surface area. The handling of shielded cables is shown in section Electrical
installation (Page 10).
Digital input = HIGH if switch closed
Digital input = HIGH if switch closed
Digital input = LOW if switch closed
Digital input = LOW if switch closed
0.5 mm² (21 AWG) ... 1.5 mm² (16 AWG)
1 mm² (18 AWG)
Installing
3.2 Electrical installation