Siemens SINAMICS G120C Getting Started page 37

Frequency converter
Hide thumbs Also See for SINAMICS G120C:
Table of Contents

Advertisement

P-No.
Note
[1] Lower limit [100 % ≙ p2003]
p1552
CI: Torque limit upper scaling without offset
[100 ≙ 100%]
p1554
CI: Torque limit lower scaling without offset
[100 ≙ 100%]
p1570
CO: Flux setpoint [100 ≙ 100%]
p1580
Efficiency optimization [%]
r1598
CO: Flux setpoint total [100 ≙ 100%]
p1610
Torque setpoint static (SLVC) [100 % ≙ r0333]
p1611
Supplementary accelerating torque (SLVC)
[100 % ≙ r0333]
r1732
CO: Direct-axis voltage setpoint [100 % ≙ p2001]
r1733
CO: Quadrature-axis voltage setpoint
[100 % ≙ p2001]
p1745
Motor model error threshold stall detection [%]
p1784
Motor model feedback scaling [%]
p1800
Pulse frequency setpoint [kHz]
r1801
CO: Pulse frequency [100 % ≙ p2000]
p1820
Reverse the output phase sequence
0
Off
1
On
p1900
Motor data identification and rotating
measurement
0
Inhibited
1
Identify the motor data at standstill and with
the motor rotating
2
Identify motor data at standstill
3
Identify motor data with the motor rotating
p1909
Motor data identification control word
p1910
Motor data identification selection
p1959
Rotating measurement configuration
p1960
Rotating measurement selection
0
Inhibited
1
Rotating measurement in encoderless
operation
3
Speed controller optimization in encoderless
operation
p1961
Saturation characteristic speed to determine [%]
p1965
Speed_ctrl_opt speed [100 % ≙ p0310]
p1967
Speed_ctrl_opt dynamic factor [%]
SINAMICS G120C frequency converter
Getting Started, 03/2012, FW V4.5, A5E03831830B AA
P-No.
Note
p2000
Reference speed reference frequency [rpm]
p2001
Reference voltage [V]
p2002
Reference current [A]
p2003
Reference torque [Nm]
r2004
Reference power
p2006
Reference temperature [°C]
p2010
Commissioning interface baud rate
p2011
Commissioning interface address
p2016
CI: Comm IF USS PZD send word
p2020
Fieldbus interface baud rate:
4
2400 baud
6
9600 baud
8
38400 baud
10 76800 baud
12 115200 baud
p2021
Fieldbus interface address
p2022
Fieldbus interface USS PZD number
p2023
Fieldbus interface USS PKW number
0
PKW 0 words
4
PKW 4 words
p2024
Fieldbus interface times [ms]
[0] Maximum processing time
[1] Character delay time
[2] Telegram pause time
r2029
Fieldbus interface error statistics
[0] Number of error-free telegrams
[1] Number of rejected telegrams
[2] Number of framing errors
[3] Number of overrun errors
[4] Number of parity errors
[5] Number of starting character errors
[6] Number of checksum errors
[7] Number of length errors
p2030
Fieldbus interface protocol selection
0
No protocol
1
USS
2
MODBUS
3
PROFIBUS
Commissioning
4.2 Further settings
5
4800 baud
7
19200 baud
9
57600 baud
11 93750 baud
13 187500 baud
3
PKW 3 words
127
PKW variable
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents