P-No.
Note
p0856
BI: Enable speed controller
p0858
BI: Unconditionally close holding brake
r0898
CO/BO: Control word sequence control
r0899
CO/BO: Status word sequence control
p0918
PROFIBUS address
p0922
PROFIdrive telegram selection
1
Standard telegram 1, PZD-2/2
20
Standard telegram 20, PZD-2/6
352
SIEMENS telegram 352, PZD-6/6:
353
SIEMENS telegram 353, PZD-2/2, PKW-
4/4
354
SIEMENS telegram 354, PZD-6/6, PKW-
4/4
999
Free telegram configuration with BICO
r0944
CO: Counter for fault buffer changes
r0945
Fault code
r0946
Fault code list
r0947
Fault number
r0948
Fault time received in milliseconds [ms]
r0949
Fault value
p0952
Fault cases, counter
r0963
PROFIBUS baud rate
r0964
Device identification
p0965
PROFIdrive profile number
p0969
System runtime relative [ms]
p0970
Reset drive parameters
0
Inactive
1
Reset start parameters
5
Starts a safety parameter reset
10
Starts to download setting 10
11
Starts to download setting 11
12
Starts to download setting 12
100
Starts a BICO interconnection reset
p0971
Save parameters
0
Inactive
1
Save drive object
SINAMICS G120C frequency converter
Getting Started, 03/2012, FW V4.5, A5E03831830B AA
P-No.
Note
10
Save in a non-volatile memory as setting
10
11
Save in a non-volatile memory as setting
11
12
Save in a non-volatile memory as setting
12
p0972
Drive unit reset
p1000
Speed setpoint selection
p1001
CO: Fixed speed setpoint 1 [rpm]
p1002
CO: Fixed speed setpoint 2 [rpm]
p1003
CO: Fixed speed setpoint 3 [rpm]
p1004
CO: Fixed speed setpoint 4 [rpm]
p1005
CO: Fixed speed setpoint 5 [rpm]
p1006
CO: Fixed speed setpoint 6 [rpm]
p1007
CO: Fixed speed setpoint 7 [rpm]
p1008
CO: Fixed speed setpoint 8 [rpm]
p1009
CO: Fixed speed setpoint 9 [rpm]
p1010
CO: Fixed speed setpoint 10 [rpm]
p1011
CO: Fixed speed setpoint 11 [rpm]
p1012
CO: Fixed speed setpoint 12 [rpm]
p1013
CO: Fixed speed setpoint 13 [rpm]
p1014
CO: Fixed speed setpoint 14 [rpm]
p1015
CO: Fixed speed setpoint 15 [rpm]
p1016
Fixed speed setpoint mode
1
Direct selection
2
Selection, binary coded
p1020
BI: Fixed speed setpoint selection bit 0
p1021
BI: Fixed speed setpoint selection bit 1
p1022
BI: Fixed speed setpoint selection bit 2
p1023
BI: Fixed speed setpoint selection bit 3
r1024
CO: Fixed speed setpoint effective [100 % ≙
p2000]
r1025
BO: Fixed speed setpoint status
p1030
Motorized potentiometer configuration
00
Storage active
01
Automatic operation, ramp-function
generator active
02
Initial rounding active
03
Storage in NVRAM active
p1035
BI: Motorized potentiometer setpoint raise
p1036
BI: Motorized potentiometer setpoint lower
Commissioning
4.2 Further settings
31

Hide quick links: