Parameter List - Siemens SINAMICS G120C Getting Started

Frequency converter
Hide thumbs Also See for SINAMICS G120C:
Table of Contents

Advertisement

4.2.3

Parameter list

The following list contains the basic parameter
information with access level 1 ... 3. The complete
parameter list is provided in the list manual, see
Product support (Page 49).
P-No.
Note
r0002
Drive operating display
p0003
Access level
p0010
Drive, commissioning parameter filter
p0015
Macro drive unit
See also Pre-defined interface configurations
(Page 14).
r0018
Control Unit firmware version
r0020
Speed setpoint smoothed [100 % ≙ p2000]
r0021
CO: Actual speed smoothed [100 % ≙ p2000]
r0022
Speed actual value rpm smoothed [rpm]
r0024
Output frequency smoothed [100 % ≙ p2000]
r0025
CO: Output voltage smoothed [100 % ≙ p2001]
r0026
CO: DC link voltage smoothed [100 % ≙ p2001]
r0027
CO: Absolute actual current smoothed
[100 % ≙ p2002]
r0031
Actual torque smoothed [100 % ≙ p2003]
r0032
CO: Active power actual value smoothed
[100 % ≙ r2004]
r0034
Motor utilization [100 ≙ 100%]
r0035
CO: Motor temperature [100°C ≙ p2006]
r0036
CO: Power unit overload I
r0039
Energy consumption
p0040
0 → 1
Reset the energy consumption display
r0041
Energy usage saved/energy saved
p0045
Smoothing time constant, display values [ms]
r0046
CO/BO: Missing enable signals
r0047
Motor data identification routine and speed
controller optimization
r0050
CO/BO: Command Data Set CDS effective
r0051
CO/BO: Drive Data Set DDS effective
r0052
CO/BO: Status word 1
.00
Ready to start
.01
Ready
.02
Operation enabled
.03
Fault active
.04
Coast down active (OFF2)
SINAMICS G120C frequency converter
Getting Started, 03/2012, FW V4.5, A5E03831830B AA
t [100 ≙ 100%]
2
P-No.
Note
.05
Quick stop active (OFF3)
.06
Closing lockout active
.07
Alarm active
.08
Deviation, setpoint/actual speed
.09
Control requested
.10
Maximum speed reached
.11
I,M,P limit reached
.12
Motor holding brake open
.13
Alarm overtemperature motor
.14
Motor rotates forwards
.15
Alarm inverter overload
r0053
CO/BO: Status word 2
r0054
CO/BO: Control word 1
.00
ON/OFF1
.01
OFF2
.02
OFF3
.03
Enable ramp-function generator
.04
Enable ramp-function generator
.05
Continue ramp-function generator
.06
Enable speed setpoint
.07
Acknowledge fault
.08
Jog bit 0
.09
Jog bit 1
.10
Master control by PLC
.11
Direction reversal (setpoint)
.13
Motorized potentiometer, raise
.14
Motorized potentiometer, lower
.15
CDS bit 0
r0055
CO/BO: Supplementary control word
.00
Fixed setpoint, bit 0
.01
Fixed setpoint, bit 1
.02
Fixed setpoint, bit 2
.03
Fixed setpoint, bit 3
.04
DDS selection, bit 0
.05
DDS selection, bit 1
.08
Technology controller enable
.09
DC braking enable
.11
Droop enable
.12
Closed-loop torque control active
.13
External fault 1 (F07860)
.15
CDS bit 1
r0056
CO/BO: Status word, closed-loop control
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents