Step
Description
6.1.5 Verify Dial-In plus Auto Blast dial scenario invoked. utilizing a network
protocol analyzer and shows SIP signalling between:
•
The TP6310 board on the Avaya G860 Media Gateway (10.1.2.63).
•
The Avaya Meeting Exchange Enterprise S6800 Application Server
(192.168.36.12).
•
The control port on the RadiSys CMS-9000 Media Server MPC in slot 2
(192.168.36.15)as per sample configuration
7. Conclusion
These Application Notes presented a compliance-tested solution comprised of the
Avaya Meeting Exchange Enterprise S6800 Conferencing Server, and the Avaya
G860 Media Gateway. This solution enables connectivity between the Avaya Meeting
Exchange Enterprise S6800 Conferencing Server directly with Avaya G860 Media
Gateway and via the Avaya SIP Enablement Services. Two tests have failed refer
Verification steps
There is issue to note from testing. Codec G.711Alaw/Mu,G.726 and G.729 was used.
G.723 codec was not supported in this test configuration
8. Additional References
Avaya references, available at http://support.avaya.com
•
Meeting Exchange S6800/S6800 5.1 Administration and Maintenance
S6800/S6800
•
Avaya Meeting Exchange Groupware Edition Version 5.1 User's Guide for
Bridge Talk
•
Avaya G860 Media Gateway 5.2 Administration and Maintenance
•
Avaya SIP Enablement Services 5.1.1 Administration and Maintenance
•
RadiSys references, available at http://RadiSys.com
RJ; Reviewed:
SPOC 3/23/2009
Solution & Interoperability Test Lab Application Notes
©2009 Avaya Inc. All Rights Reserved.
70 of 71
MXS6800SES-G860