Technical Specifications - Avaya 8200 Installing Manual

Virtual services platform
Hide thumbs Also See for 8200:
Table of Contents

Advertisement

Installing the Avaya Virtual Services Platform 8200
Figure 3: Job aid
To install the ESD discharge cable, perform this procedure.
1. Connect the ground lug on the ESD discharge cable to a safe and suitable earth ground.
2. Connect all RJ-45 cable connectors to the female RJ-45 connector of the ESD discharge
cable for at least 5 seconds, and then connect each RJ-45 cable connector to the switch.
3. Leave cables connected to the networking equipment. After you connect cables to
networking equipment, the cables do not build up charge.

Technical specifications

The following table provides the technical specifications for the individual switches in this series.
Ensure that the area where you install the switch and where it operates meets these requirements.
Warning:
To avoid bodily injury from hazardous electrical shock and current, never remove the top of the
device. No user-serviceable components are inside.
Table 5: Physical Specifications
Height
Width
Depth
Weight
Weight of spare AC power supply unit
Weight of spare DC power supply unit
Installing the Avaya VSP 8200
16
3.5 in. (88.9mm) — 2U
17.5 in. (444.5 mm) - 19" rack mountable
19.68 in. (500 mm)
32.1 lb (14.56 kg) VSP 8284XSQ (EC8200x01-E6)
1.9 lb (0.862 kg) (EC8005x01-E6)
1.76 lb (0.8 kg) (EC8005001-E6)