Technology module TM ECC PL ST (6FE1242-6TM20-0BB1)
Manual, 07/2019, A5E43919893B-AA
USINT
State of Plug Present (only relevant for Type 1 connector)
0: Vehicle is not connected to the charging station.
1: Vehicle is connected to the charging station, the button at the con-
nector is pressed
2: Vehicle is connected to the charging station, the button at the con-
nector is not pressed
0xFF: Invalid voltage at Plug Present (U > 3.5 V)
UDT_Charger_
Current manipulated variables for the charging station.
Setpoints
LWord
Pending SW errors
Int
SW states
-3: An error has occurred. The error can be acknowledged.
The status "-2" automatically changes to the status "-3" after 10 sec-
onds.
-2: An error has occurred. The charging station has shut down.
-1: An error has occurred. The charging station is shutting down.
0: Initialization phase (after cold restart). The basic HW checks are
performed.
Are all the modules on and the breakers open?
1: System ready
2: System in idle state (no charging process active).
The IO modules are off, all the breakers are open.
3: The I/O modules are on, all breakers are open.
4: System is ready for charging (communication with the vehicle has
started).
This phase is very short and therefore not always visible at the output.
5: Authentication phase (in accordance with DIN SPEC 70121)
6: Parameter discovery (in accordance with DIN SPEC 70121)
7: ExtVoltageCheck
This phase is very short and therefore not always visible at the output.
8: Cable Check (in accordance with DIN SPEC 70121)
9: PreCharge/Power Delivery (according to DIN SPEC 70121)
10: Current Demand (according to DIN SPEC 70121)
11: Termination of the charging process (according to DIN SPEC
70121)
Programming
5.5 DIN_70121 parameter