Siemens SIMATIC ET 200SP Manual page 59

Technology module tm ecc pl st
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

stopChargingCurrentInAm-
pere
supportedEnergyTransfer-
Types
Technology module TM ECC PL ST (6FE1242-6TM20-0BB1)
Manual, 07/2019, A5E43919893B-AA
UInt
If this value is undershot when the charging process is terminated, the DC
breaker is opened.
This current must be less than or equal to the value of "maxCurrentIn-
Ampere"; otherwise the error message bit 1 (parameterization error) is set.
Word
With this parameter you select the energy transfer variants supported by
the charging station
(True = selected; False = not selected).
The designations of the types are taken directly from the DIN SPEC
70121.
Bit 0 = AC_single_phase_core
is not supported in DIN SPEC 70121
Bit 1 = AC_three_phase_core
is not supported in DIN SPEC 70121
Bit 2 = DC_core
DC charging via the pins in the Type1/Type2 connector is supported
Bit 3 = DC_extended
Charging via the extended pins of the CCS connector (Type1/Type2) is
supported
Bit 4 = DC_combo_core
is not supported in DIN SPEC 70121
Bit 5 = DC_dual
is not supported in DIN SPEC 70121
Bit 6 = AC_core1p_DC_extended
is not supported in DIN SPEC 70121
Bit 7 = AC_single_DC_core
is not supported in DIN SPEC 70121
Bit 8 = AC_single_phase_three_phase_core_DC_extended
is not supported in DIN SPEC 70121
Bit 9 = AC_core3p_DC_extended
is not supported in DIN SPEC 70121
The DIN_70121 function block only supports DC_core (bit 2) and
DC_extended (bit 3). The error message bit 1 (parameterization error) is
set for all other variants (bit values). In addition, at least one of these two
bits must be set.
The variants supported by the charge column are compared to the variants
required by the vehicle. If the vehicle requires a variant which is not sup-
ported by the charge column, the charge process is aborted.
Programming
5.5 DIN_70121 parameter
57