Pressure Relief - Graco G3 Instructions Manual

Stirring paddle replacement kit
Hide thumbs Also See for G3:

Advertisement

Instructions

Pressure Relief

SKIN INJECTION HAZARD
High-pressure fluid from dispense device, hose leaks, or
ruptured components will pierce skin. This may look like
just a cut, but it is a serious injury that can result in ampu-
tation. Get immediate surgical treatment.
Follow Pressure Relief Procedure in this manual, when
you stop dispensing and before cleaning, checking, or
servicing equipment.
Relieve pressure in system by using two wrenches
working in opposite directions on pump element and
pump element fitting to only loosen fitting.
NOTE: When loosening pump element fitting, do NOT
loosen pump element. Loosening pump element will
change the output volume.
F
. 1
IG
2
Instructions
Reference numbers used in these instructions corre-
spond to parts included in Kit and are provided on page
1. Parts identified with an alpha character are user pro-
vided, already installed components or locations neces-
sary to correctly complete these instructions.
Disassembly
NOTE: Unless otherwise noted, all illustrations show 2L
pump models.
1. Disconnect power source.
2. Relieve pressure using Pressure Relief Procedure
provided.
3. For 2 Liter models only: use a strap wrench
around reservoir (a) to turn reservoir 1/4 turn coun-
ter-clockwise (F
. 2).
IG
For 4L or larger reservoirs: be sure strap wrench
is positioned around the lower portion of the reser-
voir. Turn reservoir counter-clockwise approximately
to full turns until it is loose enough to remove it from
reservoir adapter.
a
F
. 2
IG
3A0535C

Advertisement