Pressure Relief Procedure - Graco Injecto-Flo 26A485 Instructions Manual

Oil pump
Table of Contents

Advertisement

Installation
All electrical wiring must be done by a qualified elec-
trician and comply with all local codes and regula-
tions.
Instructions
1. Disconnect the power at the source.
2. Remove the 4 bolts from the cover to the junction
box and remove the cover from the motor.
3. Verify the voltage in the facility is compatible with the
voltage shown inside the plate cover on the electric
motor.
4. Connect the power supply cable as shown in the
Wiring Diagram.
NOTE: Be sure cables are securely connected to
the terminals and cannot be unintentionally discon-
nected.
5. Replace junction box cover and 4 bolts (a). Tighten
bolts securely.
6. Reconnect power to the source.
7. Verify motor rotation direction is correct (clockwise)
as shown on the motor housing.
3A5213B
Wiring Diagram
F
. 4
IG

Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever
you see this symbol.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief Pro-
cedure when you stop dispensing and before clean-
ing, checking, or servicing the equipment.
To relieve pressure:
1. Turn off main power to the motor.
After the power is turned off, the pressure will drop
partially, through the gears. This depends on the oil
viscosity, valves and gears.
2. The remaining pressure will be relieved through the
3-way valve installed in the outlet tubing.
Installation