Pressure Relief Procedure - Graco Check-Mate P05LCS Instructions And Parts

Pump package
Table of Contents

Advertisement

Pressure Relief Procedure

Pressure Relief Procedure
1. Lock the gun/valve trigger.
2. For D200s, D200, D60 and S20 Air Controls: See
F
. 6.
IG
a. Close the air motor slider valve and the main air
slider valve.
b. Set the ram director valve to DOWN. The ram
will slowly drop.
c. Jog the director valve up and down to bleed air
from ram cylinders.
ti10438a
F
. 6: Air Control Module
IG
3. For L20c Air Controls: See F
a. Close the air motor valve and the elevator direc-
tor valve. The ram will slowly drop.
12
Air Motor Valve
Ram Director
Valve
Main Air Valve
. 7.
IG
Air Motor Valve
F
. 7: L20c Air Control Panel
IG
4. Unlock the gun/valve trigger.
5. Hold a metal part of the gun/valve firmly to the side
of a grounded metal pail, and trigger the gun/valve
to relieve pressure.
6. Lock the gun/valve trigger.
7. Open the fluid line drain valve and the pump bleed
valve (P). Have a container ready to catch the drain-
age.
8. Leave the pump bleed valve open until ready to
spray again.
F
. 8
IG
If you suspect that the spray tip/nozzle or hose is com-
pletely clogged, or that pressure has not been fully
relieved after following the steps above, very slowly
loosen the tip guard retaining nut, nozzle, or hose end
coupling and relieve pressure gradually, then loosen
completely. Now clear the tip/nozzle or hose.
Elevator Director
Valve
r_257302_312376_2e
P
ti10420a
312376L

Advertisement

Table of Contents
loading

This manual is also suitable for:

Check-mate p05lcmCheck-mate p05lssCheck-mate p05lsmCheck-mate p11lcsCheck-mate p11lcmCheck-mate p11lss ... Show all

Table of Contents