Pressure Relief Procedure; Pump Shutdown - Graco Husky 2150e Operation

Hide thumbs Also See for Husky 2150e:
Table of Contents

Advertisement

Operation
Pressure Relief
Relief Procedure
Procedure
Pressure
Pressure
Relief
Procedure
Follow the Pressure Relief Procedure
whenever you see this symbol.
This equipment stays pressurized until pressure
is relieved manually. To help prevent serious
injury from pressurized fluid, such as splashing
in the eyes or on skin, follow the Pressure Relief
Procedure when you stop pumping and before you
clean, check, or service the equipment.
1. Remove power from the system.
2. Open the dispensing valve, if used.
3. Open the fluid drain valve (L), if used, to relieve
fluid pressure. Have a container ready to catch
the drainage.
4. Shut off the air supply to the pump.
5. Back out center section regulator to relieve air
pressure in center section.
20
All manuals and user guides at all-guides.com

Pump Shutdown

Pump
Pump
At the end of the work shift and before you check,
adjust, clean, or repair the system, follow the
Pressure Relief Procedure, page
Shutdown
Shutdown
20.
3A4068H

Advertisement

Table of Contents
loading

Table of Contents