Message List Of Operating Messages (Asynchronous Errors); Table 7-1 List Of Data And Operating Errors - Siemens SIWAREX MS Device Manual

Weigh module for simatic s7-200
Hide thumbs Also See for SIWAREX MS:
Table of Contents

Advertisement

Messages and Diagnosis
Error
Data and operating errors
No.
- Meaning
94
Adjustment weight too low
96
Tare T- invalid
100
Weight outside zero definition
range
171
Checksum error
172
Error saving data record
173
Data record transfer error
Table 7-1
List of data and operating errors
7.6

Message List of Operating Messages (Asynchronous Errors)

If an error generates an operating message, the red SF LED on the front of the
module is illuminated. The incoming and outgoing operating messages are
signaled in the diagnostic buffer.
Error
Operating messages
No.
- Meaning
1
Reboot due to error in RAM read-write
testing
2
Reboot due to watchdog error
3
Reboot due to program error
4
Reserved
5
Parameter error
7-40
SIWAREX MS
Description
The adjustment weight is too low in DS 3. Increase
the adjustment weight interval. The measured
values between successive adjustment weights
must have an interval of at least 5% of the
measuring range.
The subtractive tare weight has been exceeded.
This error is generated in the following cases:
The gross value lies above the defined
permitted tare range for the taring command.
An externally specified tare value is negative.
Zero definition cannot be executed since the current
zero point lies outside the zero definition range
defined in DS 3 or the current gross value lies above
the highest defined weighing range value.
Checksum error in data record 26.
The data was falsified or the DS versions do not
match.
An error occurred while saving the data record to
the Flash memory.
An error occurred while transferring the data record.
The data record was not transferred.
The error can mean that the module is
defective.
The module had to be reset because of a
critical error.
The error can mean that the module is
defective. Contact the SIWAREX Hotline.
Reserved
The parameters are not consistent (the
Description