Siemens SIWAREX U Getting Started
Hide thumbs Also See for SIWAREX U:

Advertisement

®
SIWAREX
U "Getting started"
Info
Status 08.11.2007

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIWAREX U

  • Page 1 ® SIWAREX U “Getting started” Info Status 08.11.2007...
  • Page 2 Brand names / Trademarks SIWAREX®, SIMATIC®, SIMATIC HMI® and SIMATIC NET® are trade marks of the Siemens AG. The other designations in this info may be trade marks the use of which by third persons for their own purposes might infringe proprietor rights.
  • Page 3 SIWAREX U Safety Instructions Table of Contents Preface Scope of Delivery “Getting started” for SIWAREX U Overview Information Operator Info Configuring Technical Data Issue 11/2007 SIWAREX U...
  • Page 4: Table Of Contents

    ROGRAM COPE ..........................6-18 YCLE Images FIGURE 3-1 PROGRAM STRUCTURE STEP7 FOR SIWAREX U “GETTING STARTED”..3-4 FIGURE 3-2 INITIAL COMMISSIONING WITH SIWATOOL U ..........3-5 FIGURE 4-1 START SCREEN FOR TOUCH PANEL TP270 ............4-6 FIGURE 4-2 SCREEN – MENU FOR SIWAREX U ............... 4-7 FIGURE 4-3 SCREEN –...
  • Page 5 SIWAREX U FIGURE 5-1 CALLING THE FC COMMAND MANAGER............5-15 FIGURE 5-2 STRUCTURE (UDT1) FOR COMMAND MANAGER ..........5-15 FIGURE 5-3 CALL PARAMETERS FOR FB SIWA_U..............5-16 Tables TABLE 6-1 REQUIRED MEMORY ....................6-18 TABLE 6-2 CYCLE TIME ......................6-18 SIWAREX U...
  • Page 7: Preface

    1 Preface 1.1 Purpose of the Information All of the information required for setting up the system with SIWAREX U “Getting started” is in this information. 1.2 Preparations for the “Getting started” software This demo-software shows the setup work required for the SIWAREX U in SIMATIC S7 through a set of examples.
  • Page 8: Scope Of Delivery

    SIWATOOL U Commissioning program for Windows Hardware Update (HSP) for the SIMATIC Manager hardware catalog Standard function block for operating the SIWAREX U in SIMATIC S7 (included in the project “Getting started” Device manuals in several languages System prerequisites for using SIWAREX U “Getting started”:...
  • Page 9: Overview

    SIMATIC S7 automation system or a force measurement is necessary. The SIWAREX U function module (FM) takes full advantage of all the features of the modern automation system, including the integrated communication, the diagnostic system and the configuration tools.
  • Page 10: Function

    PLC. SIWAREX U “Getting started” takes over the tasks of a standardized program in the SIMATIC S7. In SIWAREX U “Getting started”, the FB scales are called, the commands and adjustment values are passed on to the scales corresponding with the progress of the process and the data from the scales is prepared for the visualization.
  • Page 11: Commissioning- And Service With Siwatool U

    3.6 Commissioning- and Service with SIWATOOL U SIWATOOL U is part of the scope of the delivery of the SIWAREX U configuration package for SIMATIC S7 (Order number 7MH4950-1AK01). To perform commissioning, the program must be installed on a PC first. The PC and SIWAREX U are connected by the cable provided as an accessory.
  • Page 12: Operator Info

    The description corresponds with the current status of the SIWAREX U “Getting started” software. The descriptions for individual scale parameters and scale functions can be found in the SIWAREX U and are not explained individually in the display of the individual SIWAREX U “Getting started”...
  • Page 13: Menu

    The operator can control and observe from this menu screen or he can select the service section for commissioning the scale. Figure 4-2 Screen – Menu for SIWAREX U 4.5 Scale adjustment Channel 1 The following screens can be selected for scale adjustment: Figure 4-3 Screen –...
  • Page 14 Figure 4-4 Screen – Scale adjustment Page 2 Figure 4-5 Screen – Scale adjustment Page 3 SIWAREX U...
  • Page 15 Figure 4-6 Screen – Scale adjustment Page 4 Figure 4-7 Screen – Scale adjustment Page 5 SIWAREX U...
  • Page 16: Scale Limit Values

    4.6 Scale Limit values Figure 4-8 Screen – Limit values 4.7 General parameters and module info Figure 4-9 Screen - General module parameters 4-10 SIWAREX U...
  • Page 17: Touch Panel Settings

    Figure 4-10 Screen – Module info 4.8 Touch panel settings Figure 4-11 Screen - Touch panel settings SIWAREX U 4-11...
  • Page 18: Meaning Of The Function Keys

    4.9 Meaning of the Function Keys The function keys have the following meaning: View alarm buffer Reset current alarms Next page Previous page Read appropriate data record out of SIWAREX U 4-12 SIWAREX U...
  • Page 19 Send appropriate data record to SIWAREX U Scale zeroing Previous screen Quit error SIWAREX U 4-13...
  • Page 20: Configuring

    You can find the SIWAREX U module in SIMATIC HW catalogue by the Function Modules (FM) of SIMATIC S7 300 group. If you can not find SIWAREX U in the SIMATIC Manager the SIWAREX U module must first be inserted in the HW catalogue. Select the function "Install HW updates"...
  • Page 21 Command input 1 i_CMD1_Code Command code bo_CMD1_Trigger BOOL FALSE Command trigger bo_CMD1_InProgress BOOL FALSE Command in progress bo_CMD1_FinishedOk BOOL FALSE Command finished ok bo_CMD1_FinishedError BOOL FALSE Command finished with error Figure 5-2 Structure (UDT1) for command manager SIWAREX U 5-15...
  • Page 22: Calling The Scale Fb

    5.6 Configuring with WinCC flexible The software is for setup for showing a scale in TP270. The conversion to other SIMATIC HMI devices is possible. WinCC flexible offers a selection of target devices for the conversion. 5-16 SIWAREX U...
  • Page 23: Program Installation In Wincc Flexible

    Setting up another TP/OP If another SIMATIC-HMI device is used, the project must be integrated into the new environment. With the WinCC flexible Function “Change device type…” the requested HMI device can be selected from a list. SIWAREX U 5-17...
  • Page 24: Technical Data

    Memory requirements in the SIMATIC CPU: OB /FB/FC Approx. 5.5 kB Approx. 0.5 kB Program scope WinCC Approx. 300 kB flexible Table 6-1 Required memory 6.2 Cycle Time Cycle time example: Approx. 2 ms CPU315-2 DP Table 6-2 Cycle time 6-18 SIWAREX U...

Table of Contents