Messages and Diagnosis

7.5 Message List Data and Operating Errors (Synchronous Messages)

Error
Data and operating errors
No.
- Meaning
1
Unknown command code
2
Unknown data record
4
Reserved
5
Parameter transfer, transfer of
int. process values and
adjustment commands not
permitted with active write
protection
7
Command can only be
executed at standstill
8
Minimum time span between
two commands not observed
20
Command only permissible with
adjusted scale
21
Module failure
77
Reserve in DS3 – Content not
permitted.
78
Reserved
80
Incorrect standstill range
81
Incorrect decimal place
82
Numeral step not plausible
83
Filter parameter implausible
84
Characteristic value not
plausible
85
Adjustment weight implausible
86
Adjustment weight error
87
Defined percentage incorrect
88
Negative value not permitted
89
Selection code not permitted for
the TTY interface
SIWAREX MS 7-39
Description
The SIWAREX does not recognize the command
code or the data record or is unable to process the
command or data record in the current operating
status.
The specified data record does not exist.
The adjustment parameters (DS3), the int. process
values (DS26) and the adjustment commands may
only be transferred if write protection is inactive
(jumper inserted between connecting terminals 1-5).
First deactivate the write protection.
The command can only be executed when the scale
is at a standstill. Wait until it is at a standstill or
change the standstill parameters in DS3.
There must be a waiting time of at least 5 seconds
between two successive commands. This applies to
the command codes 1, 2, 3, 4, 5, 8.
Scale commands can only be executed if the
module has been calibrated.
First calibrate the module.
Command is not permissible due to a module failure.
Enter "----".
Reserved
The specified standstill range is not plausible.
The defined decimal point is not plausible for the
remote display. 0.....5 is permitted.
Numeral step is incorrect in DS 3.
The following values are possible as the numeral
step: 20, 10, 5, 2, 1.
The filter parameter definition is not plausible in DS 3.
Check the limit frequency (selection 0...9).
The characteristic value in DS3 is incorrect. Set the
parameter to a valid value (1, 2 or 4).
At least one weight setting for scale adjustment is
not plausible.
The defined adjustment weights are incorrect. The
weight values must be in ascending order or 0 if not
used.
A percentage definition is incorrect. A definition
exceeding 100% is not permitted for defining the
zero set value or the maximum tare value.
A parameter contains a negative value that is not
permitted.
The selection code for the TTY interface is not
permitted. Set a valid value (0 or 1).