MAP5000
Figure 1.2: Wiring of Power Supply Segments
Condition 2:
Charged batteries must be connected to the power supply to ensure reliable system start-up.
Figure 1.3 Batteries for System Start-Up
Condition 3:
To ensure reliable system start-up, it is necessary to take into account the cable length and
wire gauge (i.e. ohmic resistance)
(refer to Table "Cable Lengths", page 11).
Typical Configuration with ICP-MAP0110 Control Panel Enclosure
Panel / DE Module / 3 LSN Modules / max. 2 Control Centers
Bosch Sicherheitssysteme GmbH
between the power supply and first control center and
between the control centers
Installation Manual
Introduction | en
9
2014.12 | 13 | F.01U.168.332