A lw a y s turn o ff the R U N c o m m a n d b e fore ch a n g in g the settin g o f p a ra m e te rs d1 -1 8 (S p e e d R e fe ren ce S electio n M ode), b1-
01 (S p e e d R e fe ren ce Selection), o r
settings, the m o to r m a y u n e xp e c te d ly start running, a n d c o u ld re s u lt in injury.
No.
Setting 0: Operator keypad
page 154.
Setting 1: Terminals (analog input terminals)
d1: Speed Reference on page 154
Table 5.5 Analog Input Settings for Speed Reference Using Voltage Signals
Terminal
Signal Level
Signal Level Selection
Setting 2: MEMOBUS/Modbus Communications
Setting 3: Option card
(M u lti-F u nction D ig ita l Inputs). I f the R U N c o m m a n d is on w hen ch a n g in g a n y o f these