Installing and connecting the device

3.5 Connecting the device

3.5
Connecting the device
3.5.1

Notes on connection

Requirement
● The device has been installed according to the information provided in these operating
instructions.
Connecting cables
Note
Use copper cables at connectors with terminal connections
Use copper (Cu) cables for all supply lines that are connected to the device with terminals,
e.g. 24 V DC power supply cables to the 24 V DC power supply connectors.
Use only shielded standard cables as data cables, order information is available in the
section "Accessories (Page 25)".
Note
Separate SELV/PELV circuits from other electric circuits or isolate the wires.
The wiring of SELV/PELV circuits must either be separated from the wiring of other
non-SELV/PELV electric circuits, or the insulation of all conductors must be rated for the
higher voltage. Alternatively, a grounded shield or additional insulation must be installed
around the wiring for SELV/PELV circuits or the other electric circuits, based on
IEC 60364-4-41.