12 Device information

1
Type and order code
2
Design
Heat source
2.1
Model
2.2
Controller
2.3
Thermal energy meter
2.4
Installation location
2.5
Performance levels
3
Operating limits
3.1
Heating water flow
3.2
cold water (heat source)
4
Flow / sound
4.1
Heating water flow / free compression (max)
Nominal flow in accordance with EN 14511
Minimum heating water flow
4.2
Cold water flow rate / internal pressure differential
Nominal flow in accordance with EN 14511
Minimum cold water flow rate
4.3
Sound power level according to EN 12102
4.4
Sound pressure level at a distance of 1m
5
Dimensions, weight and filling quantity
2
5.1
Device dimensions
5.2
Weight of the transportable unit(s) incl. packaging
5.3
Device connections for heating
5.4
Device connections for heat source
5.5
Refrigerant / total filling weight
5.6
GWP value / CO
equivalent
2
5.7
5.8
Lubricant / total filling quantity
5.9
Volume of heating water in device
5.10 Volume of heat transfer medium in device
6
Electrical connection
6.1
Supply voltage / fuse protection / RCD-Type
6.2
Control voltage / fuse protection / RCD-Type
6.3
Degree of protection according to EN 60 529
6.4
Starting current with soft starter
6.5
Nominal power consumption W10/W35 / max. power consumption
Nominal current W10/W35 / cos 
6.6
6.7
Max. power consumption of compressor protection
(per compressor)
6.8
Power consumption of pump(s)
www.gdts.one
°C
°C
at W10...7 / W35...30
m³/h / Pa
at W10...7 / W45...40
m³/h / Pa
at W10...7 / W55...47
m³/h / Pa
at W10...7 / W65...55
m³/h / Pa
m³/h / Pa
at W10...7 / W35...30
m³/h / Pa
at W10...7 / W45...40
m³/h / Pa
at W10...7 / W55...47
m³/h / Pa
at W10...7 / W65...55
m³/h / Pa
m³/h / Pa
dB(A)
1
dB(A)
H x W x L mm
kg
inches
Inches
type/kg
--- / t
type/litres
Litres
Litres
A
3
kW
A / ---
W
kW
452234.66.57 · FD 9908
WIH 120TU
Water
Universal
integrated
Integrated
Indoors
2
20 to 70 ±2
+7 to +25
21.2 / 36500
20.8 / 38400
12.6 / 78900
9.9 / 92300
9.9 / 92300
28.1 / 30820
26.6 / 28000
24.1 / 23150
21.7 / 19230
21.7 / 19230
70
55
1890 x 1350 x 775
807
Rp 2''
Rp 3''
R134a / 24.5
1430 / 35
yes
Polyolester (POE)/16.0
22.9
23.8
3~/PE 400 V (50 Hz) / C 100A / A
1~/N/PE 230 V (50 Hz) / C 13A / A
IP 21
120
23.0 / 45.0
49.6 / 0.67
130 / thermostatically controlled
up to 0.52