13 Device information

1
Type and order code
2
Design
Heat source
2.1
Version
2.2
Controller
2.3
Thermal energy metering
2.4
Installation location
2.5
Performance level
3
Operating limits
3.1
Heating water flow/return
3.2
Cooling water flow
3.3
Air (heating)
3.4
Air (cooling)
4
Flow / sound
4.1
Heating water flow / internal pressure differential
Nominal flow according to EN 14511
Free compression
Minimum heating water flow rate / internal pressure differential
Free compression
4.2
Cooling water flow rate / internal pressure differential
Nominal flow according to EN 14511
Free compression
Minimum cooling water flow rate / internal pressure differential
Free compression
4.3
Sound power level according to EN 12102
outdoors at A7/W55
4.4
Sound pressure level in 10 m distance, outdoors
4.5
Sound power level reduced operation outdoors
4.6
Sound pressure level at a distance of 10 m,
reduced operation, outdoors
4.7
Sound power level according to EN 12102
indoors at A7/W55
4.8
Sound pressure level at a distance of 1 m, indoors
4.9
Air flow, normal operation / reduced operation
5
Dimensions, weight and filling quantities
3
5.1
Device dimensions
5.2
Weight outdoor unit / incl. packing
Weight indoor unit / incl. packing
5.3
Device connections for heating
5.4
Refrigerant / total filling weight
5.5
GWP value / CO
equivalent
2
5.6
Lubricant / total filling quantity
5.7
Volume of heating water in the outdoor unit
5.8
Buffer tank
Nominal volume
Max. permissible operating temperature
Max. permissible operating pressure
5.9
Indoor unit
Volume of heating water in the indoor unit
Heat exchanger area
Max. permissible operating temperature
Max. permissible operating pressure
5.10 Electrical pipe heater
5.11 Start-to-leak pressure, safety valve
EN-30
1
2
1 2
1
Indoor unit
Outdoor unit
--- / t
452172.66.05-EN · FD 0306
LIA 0608HXCF M
Split reversible
WPM Touch
Yes
Indoors/outdoors
Variable
° C
up to 65 / from 12
° C
7 to 25
° C
-25 to +35
° C
-5 to +43
m³/h /Pa
1.07 / 10900
Pa
63800
m³/h/Pa
0.65 / 10900
Pa
71900
m³/h/Pa
1.07 / 10900
Pa
63800
m³/h/Pa
1.07 / 10900
Pa
63800
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
m³/h
2770
657 x 444 x 261
H x W x D mm
712 x 1008 x 426
H x W x D mm
kg
60 / 65.5
kg
31.9 / 36.2
mm
Type/kg
R32 / 1.5
675 / 1.01
Type
FW68S / 0.46
Litres
Litres
°C
bar
Litres
°C
bar
kW
2, 4 or 6
bar
LIA 0608HXCF M - LIA 1316HXCF M
LIA 0911HXCF M
Air
Split reversible
WPM Touch
Indoors/outdoors
up to 65 / from 12
-25 to +35
1.72 / 26300
1.07 / 10900
1.72 / 26300
1.72 / 26300
58
30
53
25
42
31
657 x 444 x 264
865 x 1118 x 523
31.9 / 36.2
28
R32 / 1.65
FW68S / 0.46
0
25
75
3
-
-
-
-
4
2, 4 or 6
2.5
www.dimplex.de
Air
Yes
Variable
7 to 25
-5 to +43
31600
63800
31600
31600
60
32
55
27
42
31
4030
78.5 / 92
28
675 / 1.2
0
25
75
3
-
-
-
-
4