Dcp Forwarding - Siemens SCALANCE W1780 Configuration Manual

Industrial wireless lan
Table of Contents

Advertisement

Configuring with Web Based Management
6.7 "Layer 2" menu
Procedure
1. In the input cells of the table row, enter the values of the port you are configuring.
2. From the drop-down lists of the cells of the table row, select the values of the port you are
configuring.
3. Click the "Set Values" button.
6.7.4

DCP Forwarding

Applications
The DCP protocol is used by STEP 7 and the PST Tool for configuration and diagnostics. In the
delivery state, DCP is enabled on all Ethernet ports; in other words, received DCP frames are
forwarded on all ports. With this option, you can disable the sending of these frames for
individual ports, for example to prevent individual parts of the network from being configured
with the PST Tool or to divide the full network into smaller parts for configuration and
diagnostics.
All the ports of the device are displayed on this WBM page.
Description
Table 1 has the following columns:
● Column 1
Shows that the settings are valid for all ports of table 2.
● Setting
Select the setting from the drop-down list. If "No Change" is selected, the entry in table 2
remains unchanged.
● Copy to Table
When you click this button, the setting is adopted for all ports of table 2.
280
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03