Load & Save; File List - Siemens SCALANCE W1780 Configuration Manual

Industrial wireless lan
Table of Contents

Advertisement

Configuring with Web Based Management
6.5 "System" menu
Description
The page contains the following boxes:
● Commit Mode
Select the required setting from the drop-down list.
– Automatic Commit
– Manual Commit
6.5.7
Load & Save
6.5.7.1

File list

Overview of the file types
Table 6-1
HTTP
Type
Description
Config
This file contains the start configuration.
Among other things, this file contains the definitions of the
users, roles, groups and function rights. The passwords are
stored in the file "Users".
ConfigPack
Detailed configuration information. for example, start configu‐
ration, users, certificates, favorites, firmware of the device (if
saved as well).
For more detailed information on creating and using the Con‐
figPack incl. firmware, refer to the section "Maintenance
(Page 333)".
CountryList
The zip file contains the country list as a csv and as a pdf file.
Debug
This file contains information for Siemens Support.
It is encrypted and can be sent by e-mail to Siemens Support
without any security risk.
152
Each change in the WLAN settings is adopted and is immediately effective when you
click the "Set Values" button. In the default setting, the SCALANCE W device is set to
"Automatic Commit".
The changes are accepted, but are not effective immediately. The changes only take
effect when you click the "Commit Changes" button. The "Commit Changes" button is
displayed when you set "Manual Commit". In addition to this the message "Manual
Commit Mode active - Press 'Commit Changes' button to provide current configuration
to driver." appears as soon as there are WLAN changes. This message can be seen on
every WBM page until either the changes made have taken effect or the SCALANCE W
device has been restarted.
Note
When the changes take effect, the WLAN connections to all WLAN interfaces will be
interrupted for a short time. The WLAN driver is started with the new settings.
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Download
Save
X
X
--
--
Configuration Manual, 11/2019, C79000-G8976-C485-03
Delete
X
--
X
--
X
--
X
X

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w1740Scalance w1780 seriesScalance w1740 seriesScalance w1788-2 m12 eecScalance w1788-1 m12Scalance w1788-2 m12 ... Show all

Table of Contents