Configuring with Web Based Management
6.5 "System" menu
Note
Configuration data has a checksum. If you edit the files, you can no longer upload them to the
device.
6.5.7.3

TFTP

Loading and saving data via a TFTP server
On this page, you can configure the TFTP server and the file names. The WBM also allows you
to store device data in an external file on your client PC or to load such data from an external
file from the PC to the devices. This means, for example, that you can also load new firmware
from a file located on your client PC.
Firmware
The firmware is signed and encrypted. This ensures that only firmware created by Siemens can
be downloaded to the device.
Configuration files
Note
Configuration files and trial mode/Automatic Save mode
In Automatic Save mode, the data is saved automatically before the configuration files
(ConfigPack and Config) are transferred.
In Trial mode, although the changes are adopted, they are not saved in the configuration files
(ConfigPack and Config). Use the "Write Startup Config" button on the "System >
Configuration" WBM page to save changes in the configuration files.
CLI script file
You can download existing CLI configurations (RunningCLI) and upload your own CLI scripts
(Script).
Note
The downloadable CLI script is not intended to be uploaded again unchanged.
CLI commands for saving and loading files cannot be executed with the CLI script file (Script).
158
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03