Configuring with Web Based Management
6.5 "System" menu
6.5.11.2

Traps

SNMP traps for alarm events
If an alarm event occurs, a device can send SNMP traps (alarm frames) to up to ten different
management stations at the same time. Traps are only sent if the events specified in the
"Events" menu occur.
Note
Traps are only sent if you have enabled the option "SNMPv1 Traps" in the "General" tab or in
"System > Configuration".
Description
● Trap Receiver Address
Enter the IP address or the FQDN (Fully Qualified Domain Name) of the station to which the
device sends SNMP traps. You can specify up to ten different recipients servers.
The table has the following columns:
● Select
Select the row you want to delete.
● Trap Receiver Address
If necessary, change the IP address or the FQDN (Fully Qualified Domain Name) of the
stations.
● Trap
Enable or disable the sending of traps. Stations that are entered but not selected do not
receive SNMP traps.
Procedure
Creating a trap entry
1. In "Trap Receiver Address", enter the IP address or the FQDN of the station to which the
device will send traps.
2. Click the "Create" button to create a new trap entry.
184
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03