Packet Error - Siemens SCALANCE W1780 Configuration Manual

Industrial wireless lan
Table of Contents

Advertisement

Configuring with Web Based Management
6.4 "Information" menu
6.4.8.4

Packet Error

Received bad frames
This page shows how many bad frames were received per port. You cannot configure anything
on this page.
Description
● Port
Shows the available ports.
● Error types
The other columns after the port number contain the absolute numbers of the incoming
frames according to their error.
In the columns of the table, a distinction is made according to the following errors:
– CRC (Cyclic Redundancy Code)
– Undersize
– Oversize
– Fragments
– Jabbers
– Collisions
● "Reset Counters" button
Click "Reset Counters" to reset all counters. The counters are reset by a restart.
106
The packet length is between 64 and 2048 bytes. The CRC of the packet is invalid.
The packet length is less than 64 bytes. The CRC of the packet is valid.
The packet size is more than 2048 bytes. The CRC of the packet is valid.
The packet length is less than 64 bytes. The CRC of the packet is invalid.
The frame length is more than 2048 bytes. The CRC of the packet is invalid.
Frames in which a collision event was detected.
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03

Hide quick links: