Configuring with Web Based Management
5.5 "System" menu
Description
The page contains the following boxes:
● "SNMPv1/v2c/v3" drop-down list
Select the SNMP protocol from the drop-down list. The following settings are possible:
– "-" (disabled)
– SNMPv1/v2c/v3
– SNMPv3
● "SNMPv1/v2c Read Only" check box
If you enable this option, SNMPv1/v2c can only read the SNMP variables.
Note
Community String
For security reasons, do not use the standard values "public" or "private". Change the
community strings following the initial installation.
● "SNMPv1/v2c Read/Write Community String" input box
Enter the community string for read and write access of the SNMP protocol.
● "SNMPv1/v2c Read Community String" input box
Enter the community string for access of the SNMP protocol.
● "SNMPv1 Traps" check box
Enable or disable the sending of traps (alarm frames). On the "Trap" tab, specify the IP
addresses of the devices to which SNMP traps will be sent.
● "SNMPv1/v2c Trap Community String" input box
Enter the community string for sending SNMPv1/v2 messages.
Procedure
1. Select the required option from the "SNMP" drop-down list:
– "-" (disabled)
– SNMPv1/v2c/v3
– SNMPv3
2. Enable the "SNMPv1/v2c Read only" check box if you only want read access to SNMP
variables with SNMPv1/v2c.
3. Enter the required character string in the "SNMPv1/v2c Read Community String" input
box.
4. Enter the required character string in the "SNMPv1/v2c Read/Write Community String"
input box.
5. Click the "Set Values" button.
140
SNMP is disabled.
SNMPv1/v2c/v3 is supported.
Only SNMPv3 is supported.
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03