HP Aruba 6400 Series Installation And Getting Started Manual page 83

Table of Contents

Advertisement

Procedure
Removing or replacing the standby management module:
1. Put on an ESD wrist strap and connect it to the ESD connection point on the front of the chassis. (See
Attaching an ESD wrist strap.)
2. Identify the standby Management module.
The Stby LED shows a solid green and the Actv LED is dark.
3. Loosen the screws securing the standby module to the chassis.
4. Open the module levers and pull the module out of its slot. To help protect the module from ESD
damage, place it in an anti-static bag.
5. If you do not plan to install another management module in the empty slot, then secure a management
module slot cover over the slot opening.
6. To install another management module in the empty slot: ,
a. Slide the management module part-way into the standby Management module slot. (The installed
management module showing the lighted Actv LED indicates the active slot).
b. Open the module locking levers.
c. Push the module into the slot until it stops.
Chapter 9 Adding or replacing switch components
1
3
2
2
1
83

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aruba 6405Aruba 6410

Table of Contents