Siemens SIPLUS HCS Series Operating Instructions Manual page 135

Io systems for heating elements, heating control system
Hide thumbs Also See for SIPLUS HCS Series:
Table of Contents

Advertisement

Data record 101 to 132 "Field type 2"
The data records describe an HCS function and address the HCS.
Byte
0, 1
1, 2
...
44, 45
46, 47
Using these data records, fields of type 2 can be defined. This field type comprises channels
that are directly assigned.
Application range:
● Blow molding
● Formation of a layer across all POMs, for example, every first channel of a POM
Definition is performed directly via the type "Word". Up to 24 channels can be defined.
The field number corresponds to the data record number minus 100. Field number 0 cannot
be used. It exists automatically in the HCS and contains all the channels of the HCS by
default. Production and standby setpoints are preset to 100%.
All channels that are not explicitly assigned to a new field remain in this default field. If users
want to use fields, they must ensure that all existing channels are assigned to a user field.
A field can be erased by entering a 0 for all channels ("0" refers to the data record length).
Note
When one of the data records 101 to 132 is written, it is no longer possible to use the data
record for field type 1.
Data record 150 "Production field value"
The data record describes an HCS function and addresses the HCS.
Byte
0
1
...
31
Definition is via an array [1 to 32] with one element of type "Byte".
The field number corresponds to the array index.
SIPLUS HCS4300 PROFINET/PROFIBUS DP
Operating Instructions, 10/2019, A5E35452705A/005
Meaning
Number of channel 1 of field (data record number minus 100)
Number of channel 2 of field (data record number minus 100)
...
Number of channel 23 of field (data record number minus 100)
Number of channel 24 of field (data record number minus 100)
Meaning
Setpoint for field 1
Setpoint for field 2
...
Setpoint for field 32
Communications
10.2 Acyclic data exchange
133

Advertisement

Table of Contents
loading

This manual is also suitable for:

Siplus hcs4300 profinetSiplus hcs4300 profibus

Table of Contents