Baxi Ecogen 24/1.0 Installation & Servicing Instructions Manual page 9

Gas fired wall mounted condensing boiler and power generator
Table of Contents

Advertisement

 
Country ­ GB/IE ­ Natural Gas
Appliance Category
Max Gas Rate  
Both 2.68 Engine 0.82 
Injector (mm)
Engine 4.1
Inlet Pressure 
Country ­ GB/IE ­ Propane Gas
Appliance Category
Max Gas Rate 
Both 1.04  Engine 0.32
Injector (mm)
Engine 3.0
Inlet Pressure
Heat Input 
 
Heat Input 
 
Heat Output 
 
 
Heat Output 
 
 
 
Appliance Type 
Electrical Supply
(Appliance must be connected to an earthed supply)
Power Consumption 
24 model
Electrical Protection
External Fuse Rating
Internal Fuse Rating for pump & diverter
valve
Condensate Drain
To accept 21.5mm (3/4 in) plastic waste pipe
Flue Terminal Dimensions 
Diameter
Projection
Connections
Gas Supply
Central Heating Flow
Central Heating Return
Outercase Dimensions
Casing Height
Overall Height Inc Flue Elbow
Casing Width
Casing Depth
 
NOx Class
5
Central Heating Primary Circuit Sealed System only
 
bar
Safety Discharge
3
Max Operating
2.5
Min Operating
0.5
Recommended
Range 1­2
Operating
Hydraulic Resistance
See graph below
Frost Thermostat
5° C
Weights
 
Packaged Boiler Carton 117kg
Installation Lift Weight
110kg
Clearances
 
Above Casing
300 mm Min (horizontal flue)
 
200 mm Min (vertical flue)
Below Casing
200 mm Min
Front
450 mm Min (For Servicing)
Front
5 mm Min (In Operation)
L.H. Side
5 mm Min
R.H. Side
60 mm Min (In Operation)
CAT I 
2H
3
(m
/hr)
Supplementary 1.86
Supplementary 5.6
(Natural Gas ­ G20)
mbar 20
 CAT I 
3P
3
(m
/hr)
Supplementary 0.72
Supplementary 4.0
(LPG ­ G31)
 
mbar 37
(Net)
Max
kW
25.3
(Gross)
Max
kW
28.1
(Non­Condensing)
 
Max
kW
23.7
(Condensing)
 
Max
kW
24.3
C13 
C33
230V~ 50Hz
150W
IPX4
13A
3.15A
100mm
125mm
copper tails
­15mm
­22mm
­22mm
­ 950mm
­ 1135mm
­ 450mm
­ 426mm
 
Min
3.7
Min
4.1
Min
3.2
Min
3.3
C53

Advertisement