7. When a THINK Controller is mounted in a wall cradle, the 5 LED Receiver fills the space on the appliance. It acts as an indicator see fig. 43 and enables user resets to be
carried out as they cannot be performed remotely.
Wiring connections to appliance ­ see Section 16.6
Wired THINK Controller Wall Cradle Control Terminal Function
1. Power supply 12v
2. Ground (0v)
3. Data Signal (+v)
Fig. 44
10.14 To Install the 5 LED Receiver and THINK Controller
1. Isolate the appliance.
2. Remove the 5­LED Receiver from the wall cradle (as supplied).
3. Connect the wire terminals between the room unit wall cradle and the appliance controls installation area, using wire suitable for 12v. (<200m)
4. Install the wall cradle in a suitable room or hall way. (see Section 10.15)
5. Make sure the wall cradle is not in a position where it can be accidentally knocked or tampered with.
6. Remove the THINK Controller from the appliance and place it in the wall cradle.
7. Place the 5­LED Receiver onto the appliance.
8. Switch on the appliance.
9. If the THINK Controller has not been configured as a Room Sensor correctly, you may see error 84: BSB collision. If this does happen, repeat from Section 10.13
paragraph 2 while the THINK Controller is on the wall cradle. Once the parameters have been checked down power the appliance for 10 seconds and then switch the
appliance back on.
page 48
10.15 Room Unit Installation Procedure
1. Room unit location: The wall cradle should be located in the main living room while giving consideration to the following points:
The place of installation should be chosen such that the sensor can capture the room temperature as accurately as possible without getting adversely affected by
direct solar radiation or other heat or refrigeration sources (about 1.5 meters above the floor) (Fig. 45).
There must be sufficient clearance around the unit, enabling it to be fitted and removed.
Important : A TRV should not be fitted to the radiator in the same room as the room sensor. 
If a TRV has been installed on this radiator, the TRV must remain set open at all times, 
therwise the house holder will experience room temperature control problems.