10.11 Wiring Center
NOTE: As the boiler does not know what the actual room or DHW temperature is, the boiler temperature is fixed at 80°C. Appliance MUST have a permanent Live/Neutral/Earth
connection. Pump MUST be connected directly to the appliance.
System Requirement ­ The default for parameter 5700 ('1'), is setup to control through an external wiring centre. To check the parameter ­ see section 11.3.k.
As an external programmer will be used to control the central heating and domestic hot water times, the installer must make sure that the boiler THINK Controller programs time
for the central heating and DHW are set to 24h on (see User Manual).
Retro Installations
NOTE: This installation is used only if the user wishes to utilise their existing temperature and time controls.
Outside and DHW sensors cannot be used. The THINK Controller must remain on the appliance.