Governor System
NEW UPDATED DESIGN GCU Blink Codes for Software Running Codes - Activated when engine is running.
Failure Condition
Running Normally
RPM Too High
Mechanical bindage
RPM Too Low
Mechanical bindage
Missing Pulse
Faulty ECU
(Normal RPM)
Faulty ECU wiring
Missing Pulse
Faulty ECU
(RPM Too High)
Faulty ECU wiring
Missing Pulse
Faulty ECU
(RPM Too Low)
Faulty ECU wiring
Sleep Mode
Power at GCU with no ECU
pulses (left in run mode)
Watchdog Interrupt RFI interference
Overtemp
Software bug
Lightning
Overspeed (Over
External noise on ECU input
4500 RPM for 0.5
Frozen throttle plate
seconds sustained)
DLA failure
Mechanical bindage
Excessive Battery
Overcharging electrical system
Voltage (> 18v for
>18 volts
0.5 seconds)
Speed Out of
Intermittent/open connection at
Range-Low
GCU
74
Possible Causes
KohlerEngines.com
Response
Response
None
None
None
System shutdown
30 minutes OFF
Ground to kill,
N/A
close throttle plate
1 second
delay
Ground to kill,
0.5
close throttle plate
seconds
LED Diagnostics
Time
Yellow LED Green LED
BLINKS
BLINKS
ON
BLINKS
ON
BLINKS
BLINKS
ON
ON
ON
OFF
ON
OFF
BLINKS
OFF
ON
OFF
OFF
OFF
OFF
BLINKS